Orthogonal fluxgate sensor noise depends on annealing-induced magnetostriction of the core
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F21%3A00355059" target="_blank" >RIV/68407700:21230/21:00355059 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/SENSORS47087.2021.9639470" target="_blank" >https://doi.org/10.1109/SENSORS47087.2021.9639470</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/SENSORS47087.2021.9639470" target="_blank" >10.1109/SENSORS47087.2021.9639470</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Orthogonal fluxgate sensor noise depends on annealing-induced magnetostriction of the core
Popis výsledku v původním jazyce
For long time amorphous microwires with (Co 94 Fe 6 ) 72.5 Si 12.5 B 15 composition have been extensively used for magnetic sensors, such as fluxgates but also magnetoimpedance, due to their vanishing magnetostriction. In fluxgate sensors we want to minimize the magnetostriction because it couples any mechanical stress (for instance due to thermal expansion) to the magnetic characteristic of the wire making the noise of the fluxgate sensor rise. In this paper we compared two magnetic wires, one with slightly negative and one with slightly positive magnetostriction in their as cast state and we anneal them measuring then how the magnetostriction and the noise evolves as we increase the annealing time.
Název v anglickém jazyce
Orthogonal fluxgate sensor noise depends on annealing-induced magnetostriction of the core
Popis výsledku anglicky
For long time amorphous microwires with (Co 94 Fe 6 ) 72.5 Si 12.5 B 15 composition have been extensively used for magnetic sensors, such as fluxgates but also magnetoimpedance, due to their vanishing magnetostriction. In fluxgate sensors we want to minimize the magnetostriction because it couples any mechanical stress (for instance due to thermal expansion) to the magnetic characteristic of the wire making the noise of the fluxgate sensor rise. In this paper we compared two magnetic wires, one with slightly negative and one with slightly positive magnetostriction in their as cast state and we anneal them measuring then how the magnetostriction and the noise evolves as we increase the annealing time.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-19686S" target="_blank" >GA20-19686S: Analýza původu šumu u senzorů typu fluxgate</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE SENSORS 2021 proceeding
ISBN
978-1-7281-9501-8
ISSN
—
e-ISSN
1930-0395
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE Sensors
Místo vydání
Irvine, CA
Místo konání akce
Sydney
Datum konání akce
31. 10. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000755468300027