The Effect of Backsheet Repairs on Insulation Resistance in Photovoltaic Modules
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F24%3A00380215" target="_blank" >RIV/68407700:21230/24:00380215 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.aba-brno.cz/download/2024-ABAF-Proceeding.pdf" target="_blank" >https://www.aba-brno.cz/download/2024-ABAF-Proceeding.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effect of Backsheet Repairs on Insulation Resistance in Photovoltaic Modules
Popis výsledku v původním jazyce
The degradation of the backsheet layer of photovoltaic modules is a highly relevant topic today. It was not initially anticipated that the plastics and encapsulation materials used could degrade. Recent findings indicate that this degradation significantly reduces the lifespan of photovoltaic modules manufactured around 2010. Additionally, the degradation of the backsheet layer dramatically decreases the insulation resistance of individual modules and the entire chain, often leading to the disconnection of the entire string for safety reasons, causing production losses. Repairs of photovoltaic modules directly in the field are highly sought after, and assessing the increase in insulation resistance after such repairs is critical and will be the subject of the following study.
Název v anglickém jazyce
The Effect of Backsheet Repairs on Insulation Resistance in Photovoltaic Modules
Popis výsledku anglicky
The degradation of the backsheet layer of photovoltaic modules is a highly relevant topic today. It was not initially anticipated that the plastics and encapsulation materials used could degrade. Recent findings indicate that this degradation significantly reduces the lifespan of photovoltaic modules manufactured around 2010. Additionally, the degradation of the backsheet layer dramatically decreases the insulation resistance of individual modules and the entire chain, often leading to the disconnection of the entire string for safety reasons, causing production losses. Repairs of photovoltaic modules directly in the field are highly sought after, and assessing the increase in insulation resistance after such repairs is critical and will be the subject of the following study.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EH22_008%2F0004617" target="_blank" >EH22_008/0004617: Konverze a skladování energie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů