Two Tone Excitation for Fundamental Mode Orthogonal Fluxgate Gradiometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F25%3A00386481" target="_blank" >RIV/68407700:21230/25:00386481 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/SENSORS59705.2025.11331113" target="_blank" >https://doi.org/10.1109/SENSORS59705.2025.11331113</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/SENSORS59705.2025.11331113" target="_blank" >10.1109/SENSORS59705.2025.11331113</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Two Tone Excitation for Fundamental Mode Orthogonal Fluxgate Gradiometer
Popis výsledku v původním jazyce
This proceedings paper presents a novel method of excitation for fundamental mode orthogonal axial gradiometer based on single core magnetic microwire. The standard excitation of DC biased fundamental mode fluxgate is modifided to utilize two-tone sine wave excitation and two pick-up coils tuned to resonance at different frequencies. This method brings new ways for individual adjustment of gradiometer pick-up coil sensitivities, lowers the effect of spatial cross-sensitivity due to coils LC circuit mutual coupling and adds the possibility to use the two pick-up coils in series with a single preamplifier while keeping the axial gradiometer output, which further simplifies the design of the electronics.
Název v anglickém jazyce
Two Tone Excitation for Fundamental Mode Orthogonal Fluxgate Gradiometer
Popis výsledku anglicky
This proceedings paper presents a novel method of excitation for fundamental mode orthogonal axial gradiometer based on single core magnetic microwire. The standard excitation of DC biased fundamental mode fluxgate is modifided to utilize two-tone sine wave excitation and two pick-up coils tuned to resonance at different frequencies. This method brings new ways for individual adjustment of gradiometer pick-up coil sensitivities, lowers the effect of spatial cross-sensitivity due to coils LC circuit mutual coupling and adds the possibility to use the two pick-up coils in series with a single preamplifier while keeping the axial gradiometer output, which further simplifies the design of the electronics.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE Sensors
ISBN
979-8-3315-4467-6
ISSN
2168-9229
e-ISSN
2168-9229
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE Sensors
Místo vydání
Irvine, CA
Místo konání akce
Vancouver
Datum konání akce
19. 10. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—