IGCC For Brown Coals with Supercritical Steam Turbine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F04%3A00146281" target="_blank" >RIV/68407700:21260/04:00146281 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1115/GT2004-54244" target="_blank" >http://dx.doi.org/10.1115/GT2004-54244</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1115/GT2004-54244" target="_blank" >10.1115/GT2004-54244</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
IGCC For Brown Coals with Supercritical Steam Turbine
Popis výsledku v původním jazyce
The paper deals with the IGCC for brown coal (BC) with simultaneous improvement of the steam cycle by the usage of supercritical steam parameters. Two gasifiers with a fluidized bed are used with outlet syngas temperature about 900 °C. Main part of the paper is focused on the arrangement and optimization of the IGCC with net total electrical output 454.7 MW and with supercritical inlet parameters 260 bar, 580°C/600°C of steam turbine. The energy sources for the steam part of the cycle are HRSGs downstream of two gas turbines at 122.6 MW each and two raw gas coolers downstream of two gasifiers. The thermal efficiency of this IGCC is on LHV basis about 49.0%. Utilization of brown coal (BC) energy m described IGCC is by 4.7% higher than m steam power station with the same parameters. This IGCC enables reduction of CO2 emission by around 44% compared with existing power stations with thermal efficiency 34%.
Název v anglickém jazyce
IGCC For Brown Coals with Supercritical Steam Turbine
Popis výsledku anglicky
The paper deals with the IGCC for brown coal (BC) with simultaneous improvement of the steam cycle by the usage of supercritical steam parameters. Two gasifiers with a fluidized bed are used with outlet syngas temperature about 900 °C. Main part of the paper is focused on the arrangement and optimization of the IGCC with net total electrical output 454.7 MW and with supercritical inlet parameters 260 bar, 580°C/600°C of steam turbine. The energy sources for the steam part of the cycle are HRSGs downstream of two gas turbines at 122.6 MW each and two raw gas coolers downstream of two gasifiers. The thermal efficiency of this IGCC is on LHV basis about 49.0%. Utilization of brown coal (BC) energy m described IGCC is by 4.7% higher than m steam power station with the same parameters. This IGCC enables reduction of CO2 emission by around 44% compared with existing power stations with thermal efficiency 34%.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20304 - Aerospace engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of ASME Turbo Expo 2004: Power for Land, Sea and Air
ISBN
0-7918-3739-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
193-197
Název nakladatele
American Society of Mechanical Engineers - ASME
Místo vydání
New York
Místo konání akce
Vídeň
Datum konání akce