Zkoušky padostrojem používané k validaci MKP modelů lidské lebky určených pro odhad HIC
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F06%3A06126665" target="_blank" >RIV/68407700:21260/06:06126665 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Drop Test Used for Validation of {F}{E} Models of Human Head for {H}
Popis výsledku v původním jazyce
Head injuries are the most often causes of death in traffic accidents. To develop better interiors of cars or new protective devices (e.g. helmets) there is a need to quantify the mean criteria of injury. Most of today used head injury criteria use an integral value of acceleration of the head during a certain time interval. The main drawback of these criteria is the fact, that they use only linear acceleration of the head. For better HIC assessment there is a need to use different measures, e.g. combination of translational and rotational acceleration or criteria based on strain energy. For these purposes complex FE models are used. To verify the behavior of these FE models, drop tests with different drop height are usually used. The paper presents results of drop tests used to validate FE models of human head. According to data obtained from accelerometers the HIC was computed and the critical height was determined.
Název v anglickém jazyce
Drop Test Used for Validation of {F}{E} Models of Human Head for {H}
Popis výsledku anglicky
Head injuries are the most often causes of death in traffic accidents. To develop better interiors of cars or new protective devices (e.g. helmets) there is a need to quantify the mean criteria of injury. Most of today used head injury criteria use an integral value of acceleration of the head during a certain time interval. The main drawback of these criteria is the fact, that they use only linear acceleration of the head. For better HIC assessment there is a need to use different measures, e.g. combination of translational and rotational acceleration or criteria based on strain energy. For these purposes complex FE models are used. To verify the behavior of these FE models, drop tests with different drop height are usually used. The paper presents results of drop tests used to validate FE models of human head. According to data obtained from accelerometers the HIC was computed and the critical height was determined.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F05%2F1020" target="_blank" >GA103/05/1020: Deformace a porušení lidské lebky při extrémním zatížení</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Mechanics 2006
ISBN
80-86246-27-2
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
208-209
Název nakladatele
Ústav teoretické a aplikované mechaniky AV ČR
Místo vydání
Praha
Místo konání akce
Svratka
Datum konání akce
15. 5. 2006
Typ akce podle státní příslušnosti
EUR - Evropská akce