Pore Size Distribution of Human Trabecular Bone - Comparison of Intrusion Measurements with Image Analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F11%3A00180420" target="_blank" >RIV/68407700:21260/11:00180420 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378297:_____/11:00359523
Výsledek na webu
<a href="http://engmech.cz/im/doc/EM2011_proceedings.pdf" target="_blank" >http://engmech.cz/im/doc/EM2011_proceedings.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pore Size Distribution of Human Trabecular Bone - Comparison of Intrusion Measurements with Image Analysis
Popis výsledku v původním jazyce
This paper deals with pore size distribution assessment of trabecular structure of human proximal femur. Two distinct methods for estimation of the pore size distribution histograms are tested, mercury intrusion porosimetry and image analysis. For the image analysis two-dimensional images of crosssections of the specimens were used and the pore size distribution was estimated using a stereological calculation method based on the geometrical properties of an idealized pore. Comparison of the results of both methods is presented. Suitability of both methods for biological materials is discussed regarding to mechanical properties of these materials, characteristics of pores and range of pore sizes present in the structure.
Název v anglickém jazyce
Pore Size Distribution of Human Trabecular Bone - Comparison of Intrusion Measurements with Image Analysis
Popis výsledku anglicky
This paper deals with pore size distribution assessment of trabecular structure of human proximal femur. Two distinct methods for estimation of the pore size distribution histograms are tested, mercury intrusion porosimetry and image analysis. For the image analysis two-dimensional images of crosssections of the specimens were used and the pore size distribution was estimated using a stereological calculation method based on the geometrical properties of an idealized pore. Comparison of the results of both methods is presented. Suitability of both methods for biological materials is discussed regarding to mechanical properties of these materials, characteristics of pores and range of pore sizes present in the structure.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F10%2F2305" target="_blank" >GAP105/10/2305: Morfometrické a mechanické vlastnosti trabekulární kosti zjištěné pomocí metod mikromechaniky a numerického modelování</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Mechanics 2011
ISBN
978-80-87012-33-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
115-118
Název nakladatele
Ústav termomechaniky AV ČR
Místo vydání
Praha
Místo konání akce
Svartka
Datum konání akce
9. 5. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—