An Evaluation Method of Complex Movement and Dynamic Stability of the Arm During Walking Based on Gyroscope Data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F15%3A00231828" target="_blank" >RIV/68407700:21260/15:00231828 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/15:00231828
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7301091" target="_blank" >http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7301091</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An Evaluation Method of Complex Movement and Dynamic Stability of the Arm During Walking Based on Gyroscope Data
Popis výsledku v původním jazyce
The work introduces a new means for quantification of dynamic stability and upper limb movement as a whole during gait. Swinging arms during gait performed by the experiment volunteers, as a cyclic motion, was quantified using two parameters AH (the convex hull area) and already known to the medical community - ROM (range of motion) revealed a potential use of the former in the scientific community. Looking at the results of the two parameters, even though ROM has shown to seem to be comparably instrumental as it yielded surprisingly rather identical results to the AH parameter (which yielded values of subjects walking at 5 km/h about twofold larger than those in volunteers walking at 3 km/h), it still fails to examine the pair of angles at the same time due to a strong interrelation of the observed joints in volunteers. As complex upper limb movement appears to be rather uniform for both arms, no significant differences between the dominant and non-dominant arm were found. It appears
Název v anglickém jazyce
An Evaluation Method of Complex Movement and Dynamic Stability of the Arm During Walking Based on Gyroscope Data
Popis výsledku anglicky
The work introduces a new means for quantification of dynamic stability and upper limb movement as a whole during gait. Swinging arms during gait performed by the experiment volunteers, as a cyclic motion, was quantified using two parameters AH (the convex hull area) and already known to the medical community - ROM (range of motion) revealed a potential use of the former in the scientific community. Looking at the results of the two parameters, even though ROM has shown to seem to be comparably instrumental as it yielded surprisingly rather identical results to the AH parameter (which yielded values of subjects walking at 5 km/h about twofold larger than those in volunteers walking at 3 km/h), it still fails to examine the pair of angles at the same time due to a strong interrelation of the observed joints in volunteers. As complex upper limb movement appears to be rather uniform for both arms, no significant differences between the dominant and non-dominant arm were found. It appears
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20102015002" target="_blank" >VG20102015002: Osobní bezpečnostní dohledový systém pro podporu výcviku a zásahu jednotek IZS</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2015 International Conference on Applied Electronics
ISBN
978-80-261-0385-1
ISSN
1803-7232
e-ISSN
—
Počet stran výsledku
6
Strana od-do
215-220
Název nakladatele
Západočeská univerzita
Místo vydání
Plzeň
Místo konání akce
Plzeň
Datum konání akce
8. 9. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—