Popis výsledku v původním jazyce
An instrument to objectively measure driver’s fatigue and to monitor approaching micro-sleep was designed, manufactured and tested. The instrument is based on a simple infrared sensor, which consists of an emitter and detector and is based on the different reflectivity of the eye and the skin of the eyelid. The instrument records eyelid activity as the number of blinks. The device has been put into practice in the form of lensless glasses and tested in an automobile simulator at the Faculty of Transport, Czech Technical University in Prague. The results show that the system was reasonably efficient at detecting fatigue, and therefore potentially micro-sleep. However, currently it is not possible to measure the effectiveness of the system and evaluate the results in real-time.
Název v anglickém jazyce
Testing a system for predicting microsleep
Popis výsledku anglicky
An instrument to objectively measure driver’s fatigue and to monitor approaching micro-sleep was designed, manufactured and tested. The instrument is based on a simple infrared sensor, which consists of an emitter and detector and is based on the different reflectivity of the eye and the skin of the eyelid. The instrument records eyelid activity as the number of blinks. The device has been put into practice in the form of lensless glasses and tested in an automobile simulator at the Faculty of Transport, Czech Technical University in Prague. The results show that the system was reasonably efficient at detecting fatigue, and therefore potentially micro-sleep. However, currently it is not possible to measure the effectiveness of the system and evaluate the results in real-time.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika
ISSN
0301-5491
e-ISSN
—
Svazek periodika
46
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
51-54
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84997447752