OPTIMIZATION OF HOPKINSON BAR INSTRUMENTATION FOR TESTING OF CELLULAR AND LOW IMPEDANCE MATERIALS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F19%3A00331924" target="_blank" >RIV/68407700:21260/19:00331924 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.engmech.cz/improc/2019/019_Falta_104.pdf" target="_blank" >http://www.engmech.cz/improc/2019/019_Falta_104.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21495/71-0-97" target="_blank" >10.21495/71-0-97</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
OPTIMIZATION OF HOPKINSON BAR INSTRUMENTATION FOR TESTING OF CELLULAR AND LOW IMPEDANCE MATERIALS
Popis výsledku v původním jazyce
In this paper, an implementation of Split Hopkinson Pressure Bar (SHPB) and its modification Open Hopkinson Pressure Bar (OHPB) for testing of cellular structures is presented. Dynamic testing of materials with low mechanical impedance is very demanding in terms of achieving the requested experimental device performance. Key elements of the Hopkinson bar instrumentation that were successfully employed in dynamic testing of cellular materials are presented in this paper. Detailed overview of the strain-gauges instrumentation including our best practices for installation and noise reduction is provided. Information about the instrumentation of Hopkinson bar with high-speed cameras are also given. To demonstrate the performance of the proposed instrumentation some examples of a typical results are summarized in the text.
Název v anglickém jazyce
OPTIMIZATION OF HOPKINSON BAR INSTRUMENTATION FOR TESTING OF CELLULAR AND LOW IMPEDANCE MATERIALS
Popis výsledku anglicky
In this paper, an implementation of Split Hopkinson Pressure Bar (SHPB) and its modification Open Hopkinson Pressure Bar (OHPB) for testing of cellular structures is presented. Dynamic testing of materials with low mechanical impedance is very demanding in terms of achieving the requested experimental device performance. Key elements of the Hopkinson bar instrumentation that were successfully employed in dynamic testing of cellular materials are presented in this paper. Detailed overview of the strain-gauges instrumentation including our best practices for installation and noise reduction is provided. Information about the instrumentation of Hopkinson bar with high-speed cameras are also given. To demonstrate the performance of the proposed instrumentation some examples of a typical results are summarized in the text.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
21100 - Other engineering and technologies
Návaznosti výsledku
Projekt
<a href="/cs/project/GA19-23675S" target="_blank" >GA19-23675S: Moderní numerické a experimentální modelování inovativních sendvičových panelů s buněčným jádrem</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Mechanics 2019: Book of full texts
ISBN
978-80-87012-71-0
ISSN
1805-8248
e-ISSN
—
Počet stran výsledku
5
Strana od-do
97-101
Název nakladatele
Institute of Thermomechanics, AS CR, v.v.i.
Místo vydání
Prague
Místo konání akce
Svratka
Datum konání akce
13. 5. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—