Design of Mirror System for Visual Illusion Induction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F22%3A00362811" target="_blank" >RIV/68407700:21260/22:00362811 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/NTAD57912.2022.10013641" target="_blank" >https://doi.org/10.1109/NTAD57912.2022.10013641</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/NTAD57912.2022.10013641" target="_blank" >10.1109/NTAD57912.2022.10013641</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design of Mirror System for Visual Illusion Induction
Popis výsledku v původním jazyce
Negative factors affecting the flight safety need to be counteracted by measures based on an understanding of the nature of the problem. Due to the fact that visual illusions are considered a factor capable of endangering the safety of the crew and passengers, it is necessary to understand the mechanics of their creation. Therefore, this paper focuses on the device able to induce specific visual illusion by the means of moving perspective that could be used as a support during the efforts to understand the mechanism of such illusions. The mirror system with variable speed of movement is designed to induce a change of perspective and thus postural destabilization of the subject. Proposed device was tested in the experiment involving postural stability measurements in the form of centre of pressure monitoring using the balance board as the indicators of sucesfull illusion induction. The results does not confirm the ilussion induction. However, the effect of mirror movement direction is observed.
Název v anglickém jazyce
Design of Mirror System for Visual Illusion Induction
Popis výsledku anglicky
Negative factors affecting the flight safety need to be counteracted by measures based on an understanding of the nature of the problem. Due to the fact that visual illusions are considered a factor capable of endangering the safety of the crew and passengers, it is necessary to understand the mechanics of their creation. Therefore, this paper focuses on the device able to induce specific visual illusion by the means of moving perspective that could be used as a support during the efforts to understand the mechanism of such illusions. The mirror system with variable speed of movement is designed to induce a change of perspective and thus postural destabilization of the subject. Proposed device was tested in the experiment involving postural stability measurements in the form of centre of pressure monitoring using the balance board as the indicators of sucesfull illusion induction. The results does not confirm the ilussion induction. However, the effect of mirror movement direction is observed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20304 - Aerospace engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2022 New Trends in Aviation Development (NTAD)
ISBN
979-8-3503-2036-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
76-80
Název nakladatele
Czechoslovakia Section IEEE
Místo vydání
Prague
Místo konání akce
Nový Smokovec
Datum konání akce
24. 11. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—