HIGH-SPEED X-RAY RADIOGRAPHY FOR EXPERIMENTS IN IMPACT DYNAMICS USING HIGH-POWER X-RAY TUBE, CESIUM IODINE SCINTILLATOR AND LABORATORY OPTICAL CAMERA
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F23%3A00371989" target="_blank" >RIV/68407700:21260/23:00371989 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.14311/APP.2023.42.0077" target="_blank" >https://doi.org/10.14311/APP.2023.42.0077</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/APP.2023.42.0077" target="_blank" >10.14311/APP.2023.42.0077</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HIGH-SPEED X-RAY RADIOGRAPHY FOR EXPERIMENTS IN IMPACT DYNAMICS USING HIGH-POWER X-RAY TUBE, CESIUM IODINE SCINTILLATOR AND LABORATORY OPTICAL CAMERA
Popis výsledku v původním jazyce
X-ray radiography and computed tomography have become well-established methods for investigation of internal structure of objects and for defectoscopy. Recently, the methods have even been used for in-situ analysis of materials under mechanical loading. Although the techniques would be very suitable for analysis during dynamic events, their application is constrained by typical achievable frame rates. Therefore, fast imaging is usually limited to facilities providing sufficient flux like particle accelerators. In this paper, we test imaging performance of a laboratory-based setup with a high-power X-ray tube, a scintillation panel, and an optical camera. Fast-rotating object and typical specimens for impact testing are irradiated with different power settings and quality of captured images is evaluated and analyzed. It is found out that the system can be successfully used for imaging at several hundred frames per second allowing for inspection of slow impact dynamics experiments.
Název v anglickém jazyce
HIGH-SPEED X-RAY RADIOGRAPHY FOR EXPERIMENTS IN IMPACT DYNAMICS USING HIGH-POWER X-RAY TUBE, CESIUM IODINE SCINTILLATOR AND LABORATORY OPTICAL CAMERA
Popis výsledku anglicky
X-ray radiography and computed tomography have become well-established methods for investigation of internal structure of objects and for defectoscopy. Recently, the methods have even been used for in-situ analysis of materials under mechanical loading. Although the techniques would be very suitable for analysis during dynamic events, their application is constrained by typical achievable frame rates. Therefore, fast imaging is usually limited to facilities providing sufficient flux like particle accelerators. In this paper, we test imaging performance of a laboratory-based setup with a high-power X-ray tube, a scintillation panel, and an optical camera. Fast-rotating object and typical specimens for impact testing are irradiated with different power settings and quality of captured images is evaluated and analyzed. It is found out that the system can be successfully used for imaging at several hundred frames per second allowing for inspection of slow impact dynamics experiments.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GM22-18033M" target="_blank" >GM22-18033M: Dynamika rázů s využitím rychlé rentgenové radiografie a zábleskového rentgenového zdroje</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Vol. 42 (2023): 18th Youth Symposium on Experimental Solid Mechanics
ISBN
978-80-01-07237-0
ISSN
2336-5382
e-ISSN
2336-5382
Počet stran výsledku
6
Strana od-do
77-82
Název nakladatele
České vysoké učení technické v Praze
Místo vydání
Praha
Místo konání akce
Telč
Datum konání akce
11. 6. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—