Operator Support System
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F02%3A04080730" target="_blank" >RIV/68407700:21340/02:04080730 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Operator Support System
Popis výsledku v původním jazyce
The establishment of NPP Dukovany units in frequency and power control leads to new requirements on increase of the plant diagnosis level, i.e. introduction of new functions and outputs which the present system does not fulfil. Further there are new demands on higher quality and correctness of information system outputs for the operator support. It means that the plant is operated not only in the base load operational mode but in the load follow mode as well. The stability of the main unit parameters, unit power output and main steam header pressure, is the characteristics feature for this mode of operation of units with VVER 440 type of reactors. This does no more hold in the new mode in which these both principal parameters vary in dependency on thepower network frequency changes. This fact, however, has an important impact on the activities of the control room operators. Therefore, in order to help them to adapt themselves easily and without unnecessary stresses to new conditions.
Název v anglickém jazyce
Operator Support System
Popis výsledku anglicky
The establishment of NPP Dukovany units in frequency and power control leads to new requirements on increase of the plant diagnosis level, i.e. introduction of new functions and outputs which the present system does not fulfil. Further there are new demands on higher quality and correctness of information system outputs for the operator support. It means that the plant is operated not only in the base load operational mode but in the load follow mode as well. The stability of the main unit parameters, unit power output and main steam header pressure, is the characteristics feature for this mode of operation of units with VVER 440 type of reactors. This does no more hold in the new mode in which these both principal parameters vary in dependency on thepower network frequency changes. This fact, however, has an important impact on the activities of the control room operators. Therefore, in order to help them to adapt themselves easily and without unnecessary stresses to new conditions.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VS97037" target="_blank" >VS97037: Řízení jakosti při vývoji vysoce spolehlivých SW</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-7318-074-X
Místo vydání
Zlín
Název nakladatele resp. objednatele
Univerzita Tomáše Bati
Verze
Neuveden
Identifikační číslo nosiče
—