Efektivní dávka pacientovi v průběhu kardiologických intervenčních výkonů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F04%3A04101437" target="_blank" >RIV/68407700:21340/04:04101437 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effective Dose to Papient During Cardiac Interventional Procedures (PRAGUE WORKPLACES)
Popis výsledku v původním jazyce
The aim of the study was to assess effective dose to a patient during cardiac procedures, such as coronary angiography and percutaneous transiluminal angioplasty. Measurements were performed on 185 patients in four catheterization laboratories in three hospitals in Prague using the dose area product (DAP) meter. Calculations on surface and effective dose were performed with Monte-Carlo based program PCXMC. The mean DAP value per procedure determined in all workplaces ranged between 25.0 and 54.5 Gy cm2for CA and 43.0 -104.5 Gy cm2 for PTCA. In three cases, the surface dose exceeded the 2 Gy level for occurrence of transient erythema. The mean effective dose per procedure in all workplaces was determined to be in the range of 2.7 - 8.8 mSv for CA and 5.7 - 15.3 mSv for CA+PTCA combined. The results are comparable with those published by other authors.
Název v anglickém jazyce
Effective Dose to Papient During Cardiac Interventional Procedures (PRAGUE WORKPLACES)
Popis výsledku anglicky
The aim of the study was to assess effective dose to a patient during cardiac procedures, such as coronary angiography and percutaneous transiluminal angioplasty. Measurements were performed on 185 patients in four catheterization laboratories in three hospitals in Prague using the dose area product (DAP) meter. Calculations on surface and effective dose were performed with Monte-Carlo based program PCXMC. The mean DAP value per procedure determined in all workplaces ranged between 25.0 and 54.5 Gy cm2for CA and 43.0 -104.5 Gy cm2 for PTCA. In three cases, the surface dose exceeded the 2 Gy level for occurrence of transient erythema. The mean effective dose per procedure in all workplaces was determined to be in the range of 2.7 - 8.8 mSv for CA and 5.7 - 15.3 mSv for CA+PTCA combined. The results are comparable with those published by other authors.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
111
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
271-274
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—