Scintilační vlákna pro experimenty v částicové fyzice - online měření indukované absorpce v poli gama záření
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F04%3A04101796" target="_blank" >RIV/68407700:21340/04:04101796 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Scintillating Fibers for Particle Physics Experiment - On-line Induced Absorption Measurement in Gamma Radiation Field
Popis výsledku v původním jazyce
Changes in the radiation-induced transparency of scintillating and wavelength-shifting fibers were studied by means of on-line-induced absorption coefficient measurement during and after gamma irradiation. It was found that the main contribution to radiation damage was caused by reactions between luminescent molecules. The time dependence of the radiation-induced absorption coefficient was analyzed in the broad spectral range (420 - 735 nm) and compared with kinetic models of the processes of absorptioncenter build-up and recovery. The latter has been recently published for these fibers and a lower dose rate in the range of 0.002- 0.01 Gy s-1 . Good agreement was reached between the low-dose and the presented high-dose measurements (dose rate 4.2 Gy s-1 ). The parameters calculated in this kinetic model are applicable to prediction of the fiber behavior in particle physics experiments.
Název v anglickém jazyce
Scintillating Fibers for Particle Physics Experiment - On-line Induced Absorption Measurement in Gamma Radiation Field
Popis výsledku anglicky
Changes in the radiation-induced transparency of scintillating and wavelength-shifting fibers were studied by means of on-line-induced absorption coefficient measurement during and after gamma irradiation. It was found that the main contribution to radiation damage was caused by reactions between luminescent molecules. The time dependence of the radiation-induced absorption coefficient was analyzed in the broad spectral range (420 - 735 nm) and compared with kinetic models of the processes of absorptioncenter build-up and recovery. The latter has been recently published for these fibers and a lower dose rate in the range of 0.002- 0.01 Gy s-1 . Good agreement was reached between the low-dose and the presented high-dose measurements (dose rate 4.2 Gy s-1 ). The parameters calculated in this kinetic model are applicable to prediction of the fiber behavior in particle physics experiments.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
2004
Číslo periodika v rámci svazku
38
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
805-808
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—