Standardizace dozimetrie v rentgenové diagnostice
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F05%3A04115349" target="_blank" >RIV/68407700:21340/05:04115349 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/63108089:_____/05:00000009
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Standardization of Dosimetry in Diagnostic Radiology
Popis výsledku v původním jazyce
For comprehensive evaluation of radiation risk to patients due to diagnostic radiology, it is essential to have a unified system of dosimetric quantities and units. Such a system does not exist currently in this field. Commonly, it is not indicated, in which material the quantity is determined and whether the backscattered radiation is included or not A specific problem brings a use of a quantity absorbed dose under conditions, in which this quantity can not be measured because of the lack of secondaryelectron equilibrium, as it is the case at an interface between two materials. Therefore, IAEA and ICRU are preparing international recommendation for dosimetry in diagnostic radiology. It will include both the system of proper quantities and units witha methodology of measurement, and calibration of relevant dosemeters. The whole system of application specific quantities will be based on kerma, which is a primary dosimetric quantity for diagnostic radiology energy range.
Název v anglickém jazyce
Standardization of Dosimetry in Diagnostic Radiology
Popis výsledku anglicky
For comprehensive evaluation of radiation risk to patients due to diagnostic radiology, it is essential to have a unified system of dosimetric quantities and units. Such a system does not exist currently in this field. Commonly, it is not indicated, in which material the quantity is determined and whether the backscattered radiation is included or not A specific problem brings a use of a quantity absorbed dose under conditions, in which this quantity can not be measured because of the lack of secondaryelectron equilibrium, as it is the case at an interface between two materials. Therefore, IAEA and ICRU are preparing international recommendation for dosimetry in diagnostic radiology. It will include both the system of proper quantities and units witha methodology of measurement, and calibration of relevant dosemeters. The whole system of application specific quantities will be based on kerma, which is a primary dosimetric quantity for diagnostic radiology energy range.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Conference Proceedings - XXVII. Days of Radiation Protection
ISBN
80-88806-53-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
162-163
Název nakladatele
Society of Nuclear Medicine and Radiation Hygiene of Slovak Medical Association
Místo vydání
Bratislava
Místo konání akce
Liptovský Ján
Datum konání akce
28. 11. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—