Není k dispozici
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F06%3A04123403" target="_blank" >RIV/68407700:21340/06:04123403 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Responses of a long-period grating fabricated in a graded-index optical fiber to temperature and refractive-index changes
Popis výsledku v původním jazyce
Sensing experiments with a long-period grating (LPG) inscribed by a CO/sub 2/ laser in a single-mode fiber with an inverted-parabolic index profile in the fiber cladding were done. A single LPG with a period of 500 mu m was used in experiments and spectral changes of the attenuation band centered at approximately=1520 nm were measured. Responses of the LPG to temperature changes and temperature-induced refractive-index changes were investigated. An average shift of 0.56 nm/ degrees C was obtained for the bare LPG and of 0.86 nm/ degrees C for the LPG recoated with a polymeric layer. An overall shift of the central wavelengths was observed in experiments repeated after two weeks that can be attributed to post-curing processes in the polymeric layer.
Název v anglickém jazyce
Responses of a long-period grating fabricated in a graded-index optical fiber to temperature and refractive-index changes
Popis výsledku anglicky
Sensing experiments with a long-period grating (LPG) inscribed by a CO/sub 2/ laser in a single-mode fiber with an inverted-parabolic index profile in the fiber cladding were done. A single LPG with a period of 500 mu m was used in experiments and spectral changes of the attenuation band centered at approximately=1520 nm were measured. Responses of the LPG to temperature changes and temperature-induced refractive-index changes were investigated. An average shift of 0.56 nm/ degrees C was obtained for the bare LPG and of 0.86 nm/ degrees C for the LPG recoated with a polymeric layer. An overall shift of the central wavelengths was observed in experiments repeated after two weeks that can be attributed to post-curing processes in the polymeric layer.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F06%2F1851" target="_blank" >GA102/06/1851: Detekce ohybů pomocí mřížek s dlouhou periodou zapsaných pomocí CO2 laseru ve standardních a mikrostrukturních optických vláknech vybraných typů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materials Science and Engineering C, Biomimetic and Supramolecular Systems
ISSN
0928-4931
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
457-461
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—