Comparison of Ho:YAG and Er:YAG Lasers for Lithotripsy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F09%3A00156978" target="_blank" >RIV/68407700:21340/09:00156978 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Ho:YAG and Er:YAG Lasers for Lithotripsy
Popis výsledku v původním jazyce
The contemporary medicine heads towards the minimally-invasive diagnosis and treatment methods. Laser-assisted lithotripsy is a minimally-invasive method for destroying or disruption of human urinary stones. For the purpose of minimally-invasive laser light delivery the optical fibres or sealed and flexible hollow waveguides are used. In this study we have compared the ablation effect of Ho:YAG laser (with the generated wavelength 2100 nm) and Er:YAG laser (with the generated wavelength 2940 nm) on theartificial samples (special compressed plaster) and human urinary stones in vitro. The ablation or perforation rates were measured and compared for both laser systems, various pulse energy levels and various interaction samples thickness. The interactionenvironment was water with temperature 25°C. Finally both lasers were tested for human urinary stones lithotripsy in vitro.
Název v anglickém jazyce
Comparison of Ho:YAG and Er:YAG Lasers for Lithotripsy
Popis výsledku anglicky
The contemporary medicine heads towards the minimally-invasive diagnosis and treatment methods. Laser-assisted lithotripsy is a minimally-invasive method for destroying or disruption of human urinary stones. For the purpose of minimally-invasive laser light delivery the optical fibres or sealed and flexible hollow waveguides are used. In this study we have compared the ablation effect of Ho:YAG laser (with the generated wavelength 2100 nm) and Er:YAG laser (with the generated wavelength 2940 nm) on theartificial samples (special compressed plaster) and human urinary stones in vitro. The ablation or perforation rates were measured and compared for both laser systems, various pulse energy levels and various interaction samples thickness. The interactionenvironment was water with temperature 25°C. Finally both lasers were tested for human urinary stones lithotripsy in vitro.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceeding of SPIE 7161 - Photonic Therapeutics and Diagnostics V
ISBN
978-0-8194-7407-0
ISSN
1605-7422
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
San Jose, (CA)
Datum konání akce
24. 1. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—