New Technologies for Submillimeter Laser Ranging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F11%3A00180925" target="_blank" >RIV/68407700:21340/11:00180925 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.301-303.397" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMR.301-303.397</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.301-303.397" target="_blank" >10.4028/www.scientific.net/AMR.301-303.397</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New Technologies for Submillimeter Laser Ranging
Popis výsledku v původním jazyce
We are presenting the work progress and recent results in a development and construction of new technologies for submillimeter laser ranging and picosecond accuracy laser time transfer. The key hardware components: the Start detector and discriminator, the echo signal detector, the timing device and signal cablings were studied in detail. The new devices have been designed, built and tested in our lab. To minimize the systematic errors the photon counting approach has been selected. The ranging chain has been designed and optimized with a goal of single shot resolution of several millimeters and sub-millimeter normal points and overall system stability. The Start detector and discriminator are constructed as a single device to optimize their matching and maintain stability. The NPET timing system based on surface acoustic wave interpolator has a resolution of 800 fs and 4 fs long term stability.
Název v anglickém jazyce
New Technologies for Submillimeter Laser Ranging
Popis výsledku anglicky
We are presenting the work progress and recent results in a development and construction of new technologies for submillimeter laser ranging and picosecond accuracy laser time transfer. The key hardware components: the Start detector and discriminator, the echo signal detector, the timing device and signal cablings were studied in detail. The new devices have been designed, built and tested in our lab. To minimize the systematic errors the photon counting approach has been selected. The ranging chain has been designed and optimized with a goal of single shot resolution of several millimeters and sub-millimeter normal points and overall system stability. The Start detector and discriminator are constructed as a single device to optimize their matching and maintain stability. The NPET timing system based on surface acoustic wave interpolator has a resolution of 800 fs and 4 fs long term stability.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DE - Zemský magnetismus, geodesie, geografie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced Materials Research
ISSN
1022-6680
e-ISSN
—
Svazek periodika
301-303
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
5
Strana od-do
397-401
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—