Synchronously intracavity pumped dual pulse optical parametric oscillator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F11%3A00186846" target="_blank" >RIV/68407700:21340/11:00186846 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/lapl.201110074" target="_blank" >http://dx.doi.org/10.1002/lapl.201110074</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/lapl.201110074" target="_blank" >10.1002/lapl.201110074</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Synchronously intracavity pumped dual pulse optical parametric oscillator
Popis výsledku v původním jazyce
We developed an intracavity synchronously pumped optical parametrical oscillator, generating two independent trains of picosecond pulses at wavelength 1540 nm. We have improved and optimized experimental setup from the point of view of achievability of stable mode-locking and compensation of astigmatism. Present setup is as very little sensitive on the action of thermal lens generated in the Nd:YVO4 crystal by laser diode pumping radiation and it is possible to work on wider range of pump intensities without risks of detuning of mode-locking. The characteristic of laser system were measured and the influence of external conditions on dual pulse generation was studied.
Název v anglickém jazyce
Synchronously intracavity pumped dual pulse optical parametric oscillator
Popis výsledku anglicky
We developed an intracavity synchronously pumped optical parametrical oscillator, generating two independent trains of picosecond pulses at wavelength 1540 nm. We have improved and optimized experimental setup from the point of view of achievability of stable mode-locking and compensation of astigmatism. Present setup is as very little sensitive on the action of thermal lens generated in the Nd:YVO4 crystal by laser diode pumping radiation and it is possible to work on wider range of pump intensities without risks of detuning of mode-locking. The characteristic of laser system were measured and the influence of external conditions on dual pulse generation was studied.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ME10131" target="_blank" >ME10131: Pikosekundové pevnolátkové lasery a optické parametrické generátory pro senzory rotace a jiných fyzikálních veličin.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Laser Physics Letters
ISSN
1612-2011
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
839-844
Kód UT WoS článku
000298019800001