Influence of Undoped YAG Cap on Diode-pumped Composite YAG/Er:Yb:glass Laser
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F12%3A00198625" target="_blank" >RIV/68407700:21340/12:00198625 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1117/12.909125" target="_blank" >http://dx.doi.org/10.1117/12.909125</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.909125" target="_blank" >10.1117/12.909125</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Undoped YAG Cap on Diode-pumped Composite YAG/Er:Yb:glass Laser
Popis výsledku v původním jazyce
Two samples of Er-Yb doped phosphate glass were tested as a gain medium of longitudinally diode pumped laser. One sample was a simple Er:Yb:glass rod (length 2.8 mm), second sample was composite rod consisting of 2.8mm long Er:Yb:glass and 6mm long YAG crystal. Diameter of both samples was 6 mm. Dopant concentration for Er:Yb:glass was 0.75 x E20 cm-3 Er and 1.7 x E21 cm-3 Yb. The goal of the experiment was to investigate an effect of the undoped YAG cap on the Er:Yb:glass laser operation. The active medium, fixed in cupreous heatsink, was placed inside the 150mm long resonator consisted of a at pumping mirror (HR @ 1.52-1.65 um, HT @ 0.97 um) and curved output coupler (r = 150 mm, R = 97% @ 1.52-1.61 um). For Er:Yb:glass pumping a fiber coupled laserdiode, operating in pulsed regime, was used. The pumping pulse width, energy, and wavelength were 1 ms, 10 mJ, and 975 nm, respectively. The decrease of Er:Yb:glass laser output pulse energy with increasing pumping repetition rate was obs
Název v anglickém jazyce
Influence of Undoped YAG Cap on Diode-pumped Composite YAG/Er:Yb:glass Laser
Popis výsledku anglicky
Two samples of Er-Yb doped phosphate glass were tested as a gain medium of longitudinally diode pumped laser. One sample was a simple Er:Yb:glass rod (length 2.8 mm), second sample was composite rod consisting of 2.8mm long Er:Yb:glass and 6mm long YAG crystal. Diameter of both samples was 6 mm. Dopant concentration for Er:Yb:glass was 0.75 x E20 cm-3 Er and 1.7 x E21 cm-3 Yb. The goal of the experiment was to investigate an effect of the undoped YAG cap on the Er:Yb:glass laser operation. The active medium, fixed in cupreous heatsink, was placed inside the 150mm long resonator consisted of a at pumping mirror (HR @ 1.52-1.65 um, HT @ 0.97 um) and curved output coupler (r = 150 mm, R = 97% @ 1.52-1.61 um). For Er:Yb:glass pumping a fiber coupled laserdiode, operating in pulsed regime, was used. The pumping pulse width, energy, and wavelength were 1 ms, 10 mJ, and 975 nm, respectively. The decrease of Er:Yb:glass laser output pulse energy with increasing pumping repetition rate was obs
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI1%2F356" target="_blank" >FR-TI1/356: *Kompaktní nanosekundový oku bezpečný laser</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE Vol. 8235 - Solid State Lasers XXI: Technology and Devices
ISBN
978-0-8194-8878-7
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
7
Strana od-do
"82351Z"
Název nakladatele
SPIE
Místo vydání
Bellingham (stát Washington)
Místo konání akce
San Francisco, California
Datum konání akce
21. 1. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000302536200052