Amount of Substance Determination by Neutron Activation Analysis at the CTU Training Reactor VR-1
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F12%3A00200967" target="_blank" >RIV/68407700:21340/12:00200967 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/12:PU100951
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Amount of Substance Determination by Neutron Activation Analysis at the CTU Training Reactor VR-1
Popis výsledku v původním jazyce
In the workplace of the training reactor VR-1, the scin-tillation detector NaI(Tl) was not used routinely. On ac-count of better energy resolution, the semiconductor HPGe detector is successfully utilized to train students and for scientific purposes. However, in some cases of nuclear gamma-ray spectroscopy, the semiconductor HPGe detector is not possible to employ and the solution is to use the scintillation detector. This paper points to the possibility of utilizing the scintillation detector for extension the training of students and for scientific purposes. For comparison of the HPGe semiconductor and scintillation NaI(Tl) detectors, the comparative neutron activation analysis experiments for amount of substance determination in several coins and neutron field parameters measurement in experimental channel of training reactor VR-1 by dosimetry foils activation were used. Based on experimental results, the new experimental task at the training reactor VR-1 for students was prepared.
Název v anglickém jazyce
Amount of Substance Determination by Neutron Activation Analysis at the CTU Training Reactor VR-1
Popis výsledku anglicky
In the workplace of the training reactor VR-1, the scin-tillation detector NaI(Tl) was not used routinely. On ac-count of better energy resolution, the semiconductor HPGe detector is successfully utilized to train students and for scientific purposes. However, in some cases of nuclear gamma-ray spectroscopy, the semiconductor HPGe detector is not possible to employ and the solution is to use the scintillation detector. This paper points to the possibility of utilizing the scintillation detector for extension the training of students and for scientific purposes. For comparison of the HPGe semiconductor and scintillation NaI(Tl) detectors, the comparative neutron activation analysis experiments for amount of substance determination in several coins and neutron field parameters measurement in experimental channel of training reactor VR-1 by dosimetry foils activation were used. Based on experimental results, the new experimental task at the training reactor VR-1 for students was prepared.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0014%2F01%2F01" target="_blank" >ED0014/01/01: Centrum výzkumu a využití obnovitelných zdrojů energie</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 13th International Scientific Conference EPE 2012
ISBN
978-80-214-4514-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1281-1284
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
23. 5. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—