A STUDY OF COHERENT RADIATION GENERATED IN AN ABLATIVE CAPILLARY DISCHARGE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F13%3A00210001" target="_blank" >RIV/68407700:21340/13:00210001 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389021:_____/13:00452367
Výsledek na webu
<a href="http://ctn.cvut.cz/ap/download.php?id=810" target="_blank" >http://ctn.cvut.cz/ap/download.php?id=810</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A STUDY OF COHERENT RADIATION GENERATED IN AN ABLATIVE CAPILLARY DISCHARGE
Popis výsledku v původním jazyce
Feasible soft-X-ray amplification in the CVI and NVII Balmer transition is investigated in a capillary discharge. The best conditions and parameters for the experimental set-up are found for an ablative capillary. The most optimistic results have shown that the gain would be greater than one, which is the condition for successful ASE (Amplified spontaneous emission) in capillary discharges. The capillary discharge evolution is modeled using the NPINCH program, employing a one-dimensional physical modelbased on MHD equations. The information about the capillary discharge evolution is processed in the FLY, FLYPAPER, FLYSPEC programs, enabling the population to be modeled on specific levels during capillary discharge.
Název v anglickém jazyce
A STUDY OF COHERENT RADIATION GENERATED IN AN ABLATIVE CAPILLARY DISCHARGE
Popis výsledku anglicky
Feasible soft-X-ray amplification in the CVI and NVII Balmer transition is investigated in a capillary discharge. The best conditions and parameters for the experimental set-up are found for an ablative capillary. The most optimistic results have shown that the gain would be greater than one, which is the condition for successful ASE (Amplified spontaneous emission) in capillary discharges. The capillary discharge evolution is modeled using the NPINCH program, employing a one-dimensional physical modelbased on MHD equations. The information about the capillary discharge evolution is processed in the FLY, FLYPAPER, FLYSPEC programs, enabling the population to be modeled on specific levels during capillary discharge.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F12%2F2043" target="_blank" >GAP102/12/2043: Impulsní zdroj měkkého rentgenového záření pro biomedicínské aplikace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica
ISSN
1210-2709
e-ISSN
—
Svazek periodika
53
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
79-87
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—