Accidental Neutron Dosimetry with Human Hair
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F13%3A00211852" target="_blank" >RIV/68407700:21340/13:00211852 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/13:00216850
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Accidental Neutron Dosimetry with Human Hair
Popis výsledku v původním jazyce
Human hair contains sulphur, which can be activated by fast neutrons. The 32S(n,p)32P reaction with a threshold of 2.5 MeV was used for fast neutron dose estimation. It is a very important parameter for individual dose reconstruction with regards to theheterogeneity of the neutron transfer to the human body. Samples of human hair were irradiated in a radial channel of a training reactor VR-1. P-32 activity in hair was measured both, directly by means of a proportional counter, and as ash dispersed in aliquid scintillator. Based on neutron spectrum estimation, a relationship between the neutron dose and induced activity was derived. Even if the hair activation method was proposed several years ago, it is not an ordinary practice. The main purpose of the experiment was to get practical experiences and verify the proposed method in practice.
Název v anglickém jazyce
Accidental Neutron Dosimetry with Human Hair
Popis výsledku anglicky
Human hair contains sulphur, which can be activated by fast neutrons. The 32S(n,p)32P reaction with a threshold of 2.5 MeV was used for fast neutron dose estimation. It is a very important parameter for individual dose reconstruction with regards to theheterogeneity of the neutron transfer to the human body. Samples of human hair were irradiated in a radial channel of a training reactor VR-1. P-32 activity in hair was measured both, directly by means of a proportional counter, and as ash dispersed in aliquid scintillator. Based on neutron spectrum estimation, a relationship between the neutron dose and induced activity was derived. Even if the hair activation method was proposed several years ago, it is not an ordinary practice. The main purpose of the experiment was to get practical experiences and verify the proposed method in practice.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20132015119" target="_blank" >VG20132015119: Testovací zařízení nové generace MONTE-1 u školního jaderného reaktoru VR-1 umožňující pokročilé testování detekčního vybavení monitorujících a zasahujících skupin v případě jaderných havárií a vybavení sítě včasného zjištění.</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů