VLBI receiver chain monitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F13%3A00214245" target="_blank" >RIV/68407700:21340/13:00214245 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985882:_____/13:00396960
Výsledek na webu
<a href="http://dx.doi.org/10.1109/EFTF-IFC.2013.6702153" target="_blank" >http://dx.doi.org/10.1109/EFTF-IFC.2013.6702153</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EFTF-IFC.2013.6702153" target="_blank" >10.1109/EFTF-IFC.2013.6702153</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
VLBI receiver chain monitoring
Popis výsledku v původním jazyce
The most demanding goal of the Global Geodetic Observing System initiative is the definition of station positions to an accuracy of 1mm and the corresponding velocities to 0.1 mm/year. The main remaining sources of error are caused by systematics, leading to intra- and inter- technique biases. In this work, we have focused on Very Long Base Interferometry (VLBI) and phase calibration generator currently in operation. This unit is injecting calibration tones into the detection chain through an input coupler located near the input of the antenna. The tones propagate further through entire detection chain and are recorded with the observed signal. Then they are extracted in post processing. These tones are generated out of an atomic frequency standard. The supplied frequency is significantly influenced by temperature and mechanical changes since usually a long cable is employed to bring the frequency to the calibration unit. To monitor the electrical length of the cable, calibration with
Název v anglickém jazyce
VLBI receiver chain monitoring
Popis výsledku anglicky
The most demanding goal of the Global Geodetic Observing System initiative is the definition of station positions to an accuracy of 1mm and the corresponding velocities to 0.1 mm/year. The main remaining sources of error are caused by systematics, leading to intra- and inter- technique biases. In this work, we have focused on Very Long Base Interferometry (VLBI) and phase calibration generator currently in operation. This unit is injecting calibration tones into the detection chain through an input coupler located near the input of the antenna. The tones propagate further through entire detection chain and are recorded with the observed signal. Then they are extracted in post processing. These tones are generated out of an atomic frequency standard. The supplied frequency is significantly influenced by temperature and mechanical changes since usually a long cable is employed to bring the frequency to the calibration unit. To monitor the electrical length of the cable, calibration with
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2013 Joint European Frequency and Time Forum and International Frequency Control Symposium (EFTF/IFC)
ISBN
978-1-4799-0342-9
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
854-856
Název nakladatele
IEEE Ultrasonics, Ferroelectrics, and Frequency Control Society
Místo vydání
Piscataway
Místo konání akce
Prague
Datum konání akce
21. 7. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—