Neutron emission from electromagnetic dissociation of Pb nuclei at root s NN = 2.76 TeV measured with the ALICE ZDC
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F14%3A00219833" target="_blank" >RIV/68407700:21340/14:00219833 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.epj-conferences.org/articles/epjconf/pdf/2014/07/epjconf_icfp2012_00073.pdf" target="_blank" >http://www.epj-conferences.org/articles/epjconf/pdf/2014/07/epjconf_icfp2012_00073.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/20147000073" target="_blank" >10.1051/epjconf/20147000073</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Neutron emission from electromagnetic dissociation of Pb nuclei at root s NN = 2.76 TeV measured with the ALICE ZDC
Popis výsledku v původním jazyce
The ALICE Zero Degree Calorimeter system (ZDC) is composed of two identical sets of calorimeters, placed at opposite sides with respect to the interaction point, 114 meters away from it, complemented by two small forward electromagnetic calorimeters (ZEM). Each set of detectors consists of a neutron (ZN) and a proton (ZP) ZDC. They are placed at zero degrees with respect to the LHC axis and allow to detect particles emitted close to beam direction, in particular neutrons and protons emerging from hadronic heavy-ion collisions (spectator nucleons) and those emitted from electromagnetic processes. For neutrons emitted by these two processes, the ZN calorimeters have nearly 100% acceptance. During the root sNN = 2.76 TeV Pb-Pb data-taking, the ALICE Collaboration studied forward neutron emission with a dedicated trigger, requiring a minimum energy deposition in at least one of the two ZN. By exploiting also the information of the two ZEM calorimeters it has been possible to separate the c
Název v anglickém jazyce
Neutron emission from electromagnetic dissociation of Pb nuclei at root s NN = 2.76 TeV measured with the ALICE ZDC
Popis výsledku anglicky
The ALICE Zero Degree Calorimeter system (ZDC) is composed of two identical sets of calorimeters, placed at opposite sides with respect to the interaction point, 114 meters away from it, complemented by two small forward electromagnetic calorimeters (ZEM). Each set of detectors consists of a neutron (ZN) and a proton (ZP) ZDC. They are placed at zero degrees with respect to the LHC axis and allow to detect particles emitted close to beam direction, in particular neutrons and protons emerging from hadronic heavy-ion collisions (spectator nucleons) and those emitted from electromagnetic processes. For neutrons emitted by these two processes, the ZN calorimeters have nearly 100% acceptance. During the root sNN = 2.76 TeV Pb-Pb data-taking, the ALICE Collaboration studied forward neutron emission with a dedicated trigger, requiring a minimum energy deposition in at least one of the two ZN. By exploiting also the information of the two ZEM calorimeters it has been possible to separate the c
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC07048" target="_blank" >LC07048: Centrum fyziky ultra-relativistických jaderných srážek</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences
ISBN
—
ISSN
2101-6275
e-ISSN
—
Počet stran výsledku
14
Strana od-do
1-14
Název nakladatele
EDP Sciences
Místo vydání
Les Ulis Cedex A
Místo konání akce
Kolymbari
Datum konání akce
10. 6. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—