Subharmonic synchronously intracavity pumped picosecond optical parametric oscillator for intracavity phase interferometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F14%3A00221896" target="_blank" >RIV/68407700:21340/14:00221896 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1612-2011/11/12/125403" target="_blank" >http://dx.doi.org/10.1088/1612-2011/11/12/125403</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1612-2011/11/12/125403" target="_blank" >10.1088/1612-2011/11/12/125403</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Subharmonic synchronously intracavity pumped picosecond optical parametric oscillator for intracavity phase interferometry
Popis výsledku v původním jazyce
The laser system suitable for precise intracavity phase interferometry is presented. The system is based on an intracavity pumped PPLN linear optical parametrical oscillator (OPO). For synchronous pumping of OPO a SESAM-mode-locked, picosecond, diode-pumped Nd:YVO4 linear oscillator, operating at 1.06 ?m was used. The OPO cavity was set to be twice as long as the pumping Nd:YVO4 laser cavity. The pumping laser was set in such a manner that the parametric gain inside the PPLN overcame the OPO threshold only for one direction of pumping pulse propagation. This leads to the generation of two independent trains of pulses at the 1.5 ?m spectral range. To verify the system performance, a LiNbO3 electro-optic phase modulator was placed inside the OPO. The RF-signal derived from the pumping pulse train, detected by a fast photodiode and divided by two, was applied on the modulator. A stable beat-note signal between the two OPO trains was successfully measured for the first time from such a com
Název v anglickém jazyce
Subharmonic synchronously intracavity pumped picosecond optical parametric oscillator for intracavity phase interferometry
Popis výsledku anglicky
The laser system suitable for precise intracavity phase interferometry is presented. The system is based on an intracavity pumped PPLN linear optical parametrical oscillator (OPO). For synchronous pumping of OPO a SESAM-mode-locked, picosecond, diode-pumped Nd:YVO4 linear oscillator, operating at 1.06 ?m was used. The OPO cavity was set to be twice as long as the pumping Nd:YVO4 laser cavity. The pumping laser was set in such a manner that the parametric gain inside the PPLN overcame the OPO threshold only for one direction of pumping pulse propagation. This leads to the generation of two independent trains of pulses at the 1.5 ?m spectral range. To verify the system performance, a LiNbO3 electro-optic phase modulator was placed inside the OPO. The RF-signal derived from the pumping pulse train, detected by a fast photodiode and divided by two, was applied on the modulator. A stable beat-note signal between the two OPO trains was successfully measured for the first time from such a com
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GPP102%2F12%2FP645" target="_blank" >GPP102/12/P645: Synchronně čerpaný optický parametrický oscilátor pro senzory</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Laser Physics Letters
ISSN
1612-2011
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
1
Strana od-do
125403
Kód UT WoS článku
000345221300018
EID výsledku v databázi Scopus
—