NEW METHOD FOR ESTIMATION OF FLUENCE COMPLEXITY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F14%3A00224808" target="_blank" >RIV/68407700:21340/14:00224808 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
NEW METHOD FOR ESTIMATION OF FLUENCE COMPLEXITY
Popis výsledku v původním jazyce
IMRT planning and verification is a complex and time-consuming process. At busy clinics this can lead to contraindication of IMRT for patients who would otherwise profit from the technique. However, IMRT verification can be simplified without compromising patient safety. One such way is suggested in our work. A new method for estimation of fluence complexity in IMRT fields is proposed. Unlike other previously published works, it is based on portal images calculated by the PDC algorithm in Eclipse (version 8.6, Varian Medical Systems) in the plane of the EPID aS500 detector. Fluence complexity is given by the number and the amplitudes of dose gradients in these matrices. Our method is validated using a set of clinical plans where fluence has been smoothed manually so that each plan has a different level of complexity. Fluence complexity calculated with our tool is in accordance with the different levels of smoothing and correlates well with DVH parameters. Thus, it is possible to estima
Název v anglickém jazyce
NEW METHOD FOR ESTIMATION OF FLUENCE COMPLEXITY
Popis výsledku anglicky
IMRT planning and verification is a complex and time-consuming process. At busy clinics this can lead to contraindication of IMRT for patients who would otherwise profit from the technique. However, IMRT verification can be simplified without compromising patient safety. One such way is suggested in our work. A new method for estimation of fluence complexity in IMRT fields is proposed. Unlike other previously published works, it is based on portal images calculated by the PDC algorithm in Eclipse (version 8.6, Varian Medical Systems) in the plane of the EPID aS500 detector. Fluence complexity is given by the number and the amplitudes of dose gradients in these matrices. Our method is validated using a set of clinical plans where fluence has been smoothed manually so that each plan has a different level of complexity. Fluence complexity calculated with our tool is in accordance with the different levels of smoothing and correlates well with DVH parameters. Thus, it is possible to estima
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů