Zero-phonon-line pumped 100-kHz Yb:YAG thin disk regenerative amplifier
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F14%3A00367413" target="_blank" >RIV/68407700:21340/14:00367413 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1117/12.2040227" target="_blank" >https://doi.org/10.1117/12.2040227</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2040227" target="_blank" >10.1117/12.2040227</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Zero-phonon-line pumped 100-kHz Yb:YAG thin disk regenerative amplifier
Popis výsledku v původním jazyce
We are developing 100-kHz picosecond Yb:YAG thin disk regenerative amplifier with 500-W average power for medical and industrial applications. Especially in case of the next generation of semiconductor lithography, high average power solid-state laser with picosecond pulse duration as pre pulse source is a key element to realize 1-kW EUV lithography source. We compared the output characteristics of CW laser operation pumped at 940-nm and 969-nm, and measured the surface temperature of thin disk. We found that the surface temperature of thin disk pumped at 960-nm was much lower than that pumped at 940-nm. We obtained 83-W output from thin disk regenerative amplifier at the repetition rate of 100-kHz pumped at 969-nm. The measured pulse duration was 1.9-ps.
Název v anglickém jazyce
Zero-phonon-line pumped 100-kHz Yb:YAG thin disk regenerative amplifier
Popis výsledku anglicky
We are developing 100-kHz picosecond Yb:YAG thin disk regenerative amplifier with 500-W average power for medical and industrial applications. Especially in case of the next generation of semiconductor lithography, high average power solid-state laser with picosecond pulse duration as pre pulse source is a key element to realize 1-kW EUV lithography source. We compared the output characteristics of CW laser operation pumped at 940-nm and 969-nm, and measured the surface temperature of thin disk. We found that the surface temperature of thin disk pumped at 960-nm was much lower than that pumped at 940-nm. We obtained 83-W output from thin disk regenerative amplifier at the repetition rate of 100-kHz pumped at 969-nm. The measured pulse duration was 1.9-ps.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proc. SPIE 8959, Solid State Lasers XXIII: Technology and Devices
ISBN
978-0-8194-9872-4
ISSN
0277-786X
e-ISSN
1996-756X
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
SPIE
Místo vydání
Bellingham (stát Washington)
Místo konání akce
San Francisco, CA
Datum konání akce
7. 2. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000335902300063