The matrix influence on the determination of low uranium concentrations by laser induced fluorescence method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F15%3A00221898" target="_blank" >RIV/68407700:21340/15:00221898 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s10967-014-3746-1" target="_blank" >http://dx.doi.org/10.1007/s10967-014-3746-1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10967-014-3746-1" target="_blank" >10.1007/s10967-014-3746-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The matrix influence on the determination of low uranium concentrations by laser induced fluorescence method
Popis výsledku v původním jazyce
A measurement technique enabling the determination of low uranium concentration utilizing system used for time resolved laser induced fluorescence spectroscopy (TRLFS), based on a commercially available kinetic phosphorescence analysis method has been developed. The effect of the matrix, complexing agent, and the level of acidification on the fluorescence spectra and integral intensity was studied. The method is highly influenced by the sample matrix; particularly if different starting uranium salts arein the calibration solutions and in the samples. In the initial study of these effects, TRLFS measurements have been used in order to clarify this behavior.
Název v anglickém jazyce
The matrix influence on the determination of low uranium concentrations by laser induced fluorescence method
Popis výsledku anglicky
A measurement technique enabling the determination of low uranium concentration utilizing system used for time resolved laser induced fluorescence spectroscopy (TRLFS), based on a commercially available kinetic phosphorescence analysis method has been developed. The effect of the matrix, complexing agent, and the level of acidification on the fluorescence spectra and integral intensity was studied. The method is highly influenced by the sample matrix; particularly if different starting uranium salts arein the calibration solutions and in the samples. In the initial study of these effects, TRLFS measurements have been used in order to clarify this behavior.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Radioanalytical and Nuclear Chemistry
ISSN
0236-5731
e-ISSN
—
Svazek periodika
304
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
HU - Maďarsko
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000351755200018
EID výsledku v databázi Scopus
2-s2.0-84939964956