Investigating stress shielding spanned by biomimetic polymer-composite vs. metallic hip stem: A computational study using mechano-biochemical model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F15%3A00228090" target="_blank" >RIV/68407700:21340/15:00228090 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jmbbm.2014.09.019" target="_blank" >http://dx.doi.org/10.1016/j.jmbbm.2014.09.019</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmbbm.2014.09.019" target="_blank" >10.1016/j.jmbbm.2014.09.019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Investigating stress shielding spanned by biomimetic polymer-composite vs. metallic hip stem: A computational study using mechano-biochemical model
Popis výsledku v původním jazyce
Periprosthetic bone loss in response to total hip arthroplasty is a serious complication compromising patient's life quality as it may cause the premature failure of the implant. Stress shielding as a result of an uneven load sharing between the hip implant and the bone is a key factor leading to bone density decrease. A number of composite hip implants have been designed so far to improve load sharing characteristics. However, they have rarely been investigated from the bone remodeling point of view topredict a long-term response. This is the first study that employed a mechano-biochemical model, which considers the coupling effect between mechanical loading and bone biochemistry, to investigate bone remodeling after composite hip implantation. In this study, periprosthetic bone remodeling in the presence of Carbon fiber polyamide 12 (CF/PA12), CoCrMo and Ti alloy implants was predicted and compared. Our findings revealed that the most significant periprosthetic bone loss in response
Název v anglickém jazyce
Investigating stress shielding spanned by biomimetic polymer-composite vs. metallic hip stem: A computational study using mechano-biochemical model
Popis výsledku anglicky
Periprosthetic bone loss in response to total hip arthroplasty is a serious complication compromising patient's life quality as it may cause the premature failure of the implant. Stress shielding as a result of an uneven load sharing between the hip implant and the bone is a key factor leading to bone density decrease. A number of composite hip implants have been designed so far to improve load sharing characteristics. However, they have rarely been investigated from the bone remodeling point of view topredict a long-term response. This is the first study that employed a mechano-biochemical model, which considers the coupling effect between mechanical loading and bone biochemistry, to investigate bone remodeling after composite hip implantation. In this study, periprosthetic bone remodeling in the presence of Carbon fiber polyamide 12 (CF/PA12), CoCrMo and Ti alloy implants was predicted and compared. Our findings revealed that the most significant periprosthetic bone loss in response
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the Mechanical Behavior of Biomedical Materials
ISSN
1751-6161
e-ISSN
—
Svazek periodika
41
Číslo periodika v rámci svazku
Jan
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
56-67
Kód UT WoS článku
000346217400006
EID výsledku v databázi Scopus
—