EURADOS 241Am skull measurement intercomparison
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F15%3A00238826" target="_blank" >RIV/68407700:21340/15:00238826 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/86652052:_____/15:#0000367
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.radmeas.2015.07.011" target="_blank" >http://dx.doi.org/10.1016/j.radmeas.2015.07.011</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2015.07.011" target="_blank" >10.1016/j.radmeas.2015.07.011</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EURADOS 241Am skull measurement intercomparison
Popis výsledku v původním jazyce
In 2011 a measurement intercomparison was launched by EURADOS WG7, with the objective of providing the participants with the tools to calibrate their detection systems for detection of 241Am in the skull bone, and evaluate the variability due to the used of the different calibration phantoms. Three skull phantoms were used in this intercomparison: the USTUR Case 0102 skull phantom, the BfS skull phantom and the CSR skull phantom. Very good agreement was found between the results of the twelve participating laboratories, with relative deviations of less than 15% for the BfS phantom and less than 17% for the USTUR phantom when measurement efficiency in defined positions was compared. However, the phantoms’ measured absolute 241Am activities showed discrepancies of up to a factor of 3.4. This is mainly due to the physical differences between the standard calibration phantoms used by the participants and those used in this intercomparison exercise.
Název v anglickém jazyce
EURADOS 241Am skull measurement intercomparison
Popis výsledku anglicky
In 2011 a measurement intercomparison was launched by EURADOS WG7, with the objective of providing the participants with the tools to calibrate their detection systems for detection of 241Am in the skull bone, and evaluate the variability due to the used of the different calibration phantoms. Three skull phantoms were used in this intercomparison: the USTUR Case 0102 skull phantom, the BfS skull phantom and the CSR skull phantom. Very good agreement was found between the results of the twelve participating laboratories, with relative deviations of less than 15% for the BfS phantom and less than 17% for the USTUR phantom when measurement efficiency in defined positions was compared. However, the phantoms’ measured absolute 241Am activities showed discrepancies of up to a factor of 3.4. This is mainly due to the physical differences between the standard calibration phantoms used by the participants and those used in this intercomparison exercise.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DL - Jaderné odpady, radioaktivní znečištění a kontrola
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20122014093" target="_blank" >VG20122014093: Systém pro měření vnitřní kontaminace po havárii JEZ zaměřený na štítné žlázy u dětí a kontaminaci transurany</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
82
Číslo periodika v rámci svazku
NOV
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
64-73
Kód UT WoS článku
000366079300011
EID výsledku v databázi Scopus
2-s2.0-84941109079