A rapid determination of Ra-226 in water using composite ion exchanger MnO2-PAN
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F15%3A00240314" target="_blank" >RIV/68407700:21340/15:00240314 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1007/s10967-014-3454-x" target="_blank" >https://doi.org/10.1007/s10967-014-3454-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10967-014-3454-x" target="_blank" >10.1007/s10967-014-3454-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A rapid determination of Ra-226 in water using composite ion exchanger MnO2-PAN
Popis výsledku v původním jazyce
A rapid method for Ra-226 determination in water samples up to 10 L using MnO2-PAN (polyacrylonitrile) composite ion absorber was proposed and verified. Samples were traced with Ba-133 to monitor radium radiochemical recoveries which were in the range of (92-100) %. MnO2-PAN absorber with grain size < 0.1 mm with bed volume (BV) 2 mL was used for Ra-226 preconcentration from water samples (pH 6.5-7.0) at flow rate < 290 BV h(-1). Radium was eluted from the absorber with 20 mL of 6.5 M HCl at flow rate of 1.5 mL min(-1). Alpha-spectrometric counting of Ba(Ra)SO4 microprecipitate was used for Ra-226 determination. The developed method was used for the Ra-226 determination in 15 samples of natural mineral, mountain spring, drinking and natural healing waters from Slovakia, Slovenia and Czech Republic.
Název v anglickém jazyce
A rapid determination of Ra-226 in water using composite ion exchanger MnO2-PAN
Popis výsledku anglicky
A rapid method for Ra-226 determination in water samples up to 10 L using MnO2-PAN (polyacrylonitrile) composite ion absorber was proposed and verified. Samples were traced with Ba-133 to monitor radium radiochemical recoveries which were in the range of (92-100) %. MnO2-PAN absorber with grain size < 0.1 mm with bed volume (BV) 2 mL was used for Ra-226 preconcentration from water samples (pH 6.5-7.0) at flow rate < 290 BV h(-1). Radium was eluted from the absorber with 20 mL of 6.5 M HCl at flow rate of 1.5 mL min(-1). Alpha-spectrometric counting of Ba(Ra)SO4 microprecipitate was used for Ra-226 determination. The developed method was used for the Ra-226 determination in 15 samples of natural mineral, mountain spring, drinking and natural healing waters from Slovakia, Slovenia and Czech Republic.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI3%2F245" target="_blank" >FR-TI3/245: Výzkum a vývoj technologií a systému nakládání s RAO ve vazbě na nové jaderné zdroje</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Radioanalytical and Nuclear Chemistry
ISSN
0236-5731
e-ISSN
1588-2780
Svazek periodika
303
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
47-51
Kód UT WoS článku
000347294600006
EID výsledku v databázi Scopus
2-s2.0-85027931939