Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F15%3A00241565" target="_blank" >RIV/68407700:21340/15:00241565 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389005:_____/15:00444984
Výsledek na webu
<a href="http://dx.doi.org/10.1118/1.4916667" target="_blank" >http://dx.doi.org/10.1118/1.4916667</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1118/1.4916667" target="_blank" >10.1118/1.4916667</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems
Popis výsledku v původním jazyce
Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9-Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H*(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs-tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye (TM) NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific (TM) FH-40G survey meter. Experiments involved a
Název v anglickém jazyce
Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems
Popis výsledku anglicky
Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9-Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H*(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs-tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye (TM) NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific (TM) FH-40G survey meter. Experiments involved a
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medical Physics
ISSN
0094-2405
e-ISSN
—
Svazek periodika
42
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
13
Strana od-do
2572-2584
Kód UT WoS článku
000354776800046
EID výsledku v databázi Scopus
2-s2.0-84928728630