Elastic Modulus, Fracture Toughness, and Fatigue Crack Growth Rate of Self Standing Cold Sprayed Deposits
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F18%3A00326110" target="_blank" >RIV/68407700:21340/18:00326110 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Elastic Modulus, Fracture Toughness, and Fatigue Crack Growth Rate of Self Standing Cold Sprayed Deposits
Popis výsledku v původním jazyce
Recently developed measurement techniques for estimation of elastic modulus, crack growth rate curves and fracture toughness were applied to cold sprayed Ni, Ti, Al and Cu deposits and to their cold rolled counterparts. The specimen shape for all measurements was rectangular bar of dimension 4x3x32 mm. Both elastic modulus measurement and crack growth rate tests were performed using resonance in pure bending with stress ratio R ~ -1. The resonance was used for loading of the sample as well as for crack length measurement. Fracture toughness was measured with fatigue pre-cracked samples using three-point bending. The crack length as well as the value of J integral were obtained by digital image correlation. The results indicate, that even though the elastic modulus of cold sprayed deposits can approach the bulk values, their fatigue fracture mechanical performance may be significantly lower than their cold rolled counterparts.
Název v anglickém jazyce
Elastic Modulus, Fracture Toughness, and Fatigue Crack Growth Rate of Self Standing Cold Sprayed Deposits
Popis výsledku anglicky
Recently developed measurement techniques for estimation of elastic modulus, crack growth rate curves and fracture toughness were applied to cold sprayed Ni, Ti, Al and Cu deposits and to their cold rolled counterparts. The specimen shape for all measurements was rectangular bar of dimension 4x3x32 mm. Both elastic modulus measurement and crack growth rate tests were performed using resonance in pure bending with stress ratio R ~ -1. The resonance was used for loading of the sample as well as for crack length measurement. Fracture toughness was measured with fatigue pre-cracked samples using three-point bending. The crack length as well as the value of J integral were obtained by digital image correlation. The results indicate, that even though the elastic modulus of cold sprayed deposits can approach the bulk values, their fatigue fracture mechanical performance may be significantly lower than their cold rolled counterparts.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20506 - Coating and films
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů