Pseudo-3D IMRT verification with EBT3 radiochromic film
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F19%3A00340472" target="_blank" >RIV/68407700:21340/19:00340472 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/86652052:_____/19:N0000049
Výsledek na webu
<a href="https://doi.org/10.1093/rpd/ncz232" target="_blank" >https://doi.org/10.1093/rpd/ncz232</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz232" target="_blank" >10.1093/rpd/ncz232</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pseudo-3D IMRT verification with EBT3 radiochromic film
Popis výsledku v původním jazyce
This work proposes a new method for pseudo-3D verification of intensity-modulated radiation therapy (IMRT) dose distributions. Unlike commercial solutions, it uses measured doses only for gamma evaluation. Its resolution is far better than with electronic detectors within the measured plane and comparable in other directions. It is readily available at clinics because it uses existing resources—a slab phantom and EBT3 films. The method was tested on six IMRT clinical cases. An in-house code for 2D and pseudo-3D gamma analysis was written in MATLAB and compared to OmniPro I’mRT.
Název v anglickém jazyce
Pseudo-3D IMRT verification with EBT3 radiochromic film
Popis výsledku anglicky
This work proposes a new method for pseudo-3D verification of intensity-modulated radiation therapy (IMRT) dose distributions. Unlike commercial solutions, it uses measured doses only for gamma evaluation. Its resolution is far better than with electronic detectors within the measured plane and comparable in other directions. It is readily available at clinics because it uses existing resources—a slab phantom and EBT3 films. The method was tested on six IMRT clinical cases. An in-house code for 2D and pseudo-3D gamma analysis was written in MATLAB and compared to OmniPro I’mRT.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000778" target="_blank" >EF16_019/0000778: Centrum pokročilých aplikovaných přírodních věd</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
362-366
Kód UT WoS článku
000530582200044
EID výsledku v databázi Scopus
2-s2.0-85082780300