Total ionization dose radiation tests results of the epoch timing system with sub-picosecond resolution and stability for its applications in space missions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F22%3A00359494" target="_blank" >RIV/68407700:21340/22:00359494 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1063/5.0094520" target="_blank" >https://doi.org/10.1063/5.0094520</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0094520" target="_blank" >10.1063/5.0094520</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Total ionization dose radiation tests results of the epoch timing system with sub-picosecond resolution and stability for its applications in space missions
Popis výsledku v původním jazyce
We report on the concept, design, and tests of a New Picosecond Event Timer (NPET) device and its response to the total ionizing dose. These radiation tests aimed to verify that the existing version of the NPET device may be used in space missions. The device was subjected to radiation of a total dose of 74 Gy provided by a 60Co source. The epoch timing part of the device was not detectably affected by the radiation dose. After the radiation dose, the epoch timing of single measurement resolution is better than 0.9 ps with the overall timing stability characterized by Time Deviation being better than 5 fs for averaging times of 100 s. The completed device tests and results indicate the possibility of using the existing version of the New Pico Event Timing device electronics for a space mission in which the total radiation dose will not exceed 74 Gy value.
Název v anglickém jazyce
Total ionization dose radiation tests results of the epoch timing system with sub-picosecond resolution and stability for its applications in space missions
Popis výsledku anglicky
We report on the concept, design, and tests of a New Picosecond Event Timer (NPET) device and its response to the total ionizing dose. These radiation tests aimed to verify that the existing version of the NPET device may be used in space missions. The device was subjected to radiation of a total dose of 74 Gy provided by a 60Co source. The epoch timing part of the device was not detectably affected by the radiation dose. After the radiation dose, the epoch timing of single measurement resolution is better than 0.9 ps with the overall timing stability characterized by Time Deviation being better than 5 fs for averaging times of 100 s. The completed device tests and results indicate the possibility of using the existing version of the New Pico Event Timing device electronics for a space mission in which the total radiation dose will not exceed 74 Gy value.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
1089-7623
Svazek periodika
93
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000912726400001
EID výsledku v databázi Scopus
2-s2.0-85137735234