SUBTRACTIVE GAMMA DISCRIMINATION TECHNIQUE FOR NEUTRON DIAMOND DETECTORS OPERATING IN MIXED RADIATION FIELDS
Popis výsledku v původním jazyce
A detection system based on diamond detectors and subtractive discrimination was developed for the measurement of thermal neutrons flux distribution changes during rod drop transient at the VR-1 reactor. The detection system was modified to replace the pulse-shaped method used for discrimination. The electronic available at the department was not able to measure high count rates with the pulse shape discrimination method. Subtractive discrimination allows us to reduce the requirements in the signal processing area, as the shape does not need to be a recorder, and therefore the digitizer performance can be significantly lower. For this reason, a pulse stretching amplifier was developed and tested.
Název v anglickém jazyce
SUBTRACTIVE GAMMA DISCRIMINATION TECHNIQUE FOR NEUTRON DIAMOND DETECTORS OPERATING IN MIXED RADIATION FIELDS
Popis výsledku anglicky
A detection system based on diamond detectors and subtractive discrimination was developed for the measurement of thermal neutrons flux distribution changes during rod drop transient at the VR-1 reactor. The detection system was modified to replace the pulse-shaped method used for discrimination. The electronic available at the department was not able to measure high count rates with the pulse shape discrimination method. Subtractive discrimination allows us to reduce the requirements in the signal processing area, as the shape does not need to be a recorder, and therefore the digitizer performance can be significantly lower. For this reason, a pulse stretching amplifier was developed and tested.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Šimáně 2025 – International Conference on Nuclear Engineering
ISBN
978-80-01-07515-9
ISSN
2336-5382
e-ISSN
2336-5382
Počet stran výsledku
7
Strana od-do
49-55
Název nakladatele
Faculty of Nuclear Sciences and Physical Engineering (Czech Technical Univ.)
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
17. 6. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—