Short-Pulse, High Brightness X-ray Production with the PLEIADES Thomson Scattering Source
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F04%3A00130221" target="_blank" >RIV/68407700:21460/04:00130221 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Short-Pulse, High Brightness X-ray Production with the PLEIADES Thomson Scattering Source
Popis výsledku v původním jazyce
PLEIADES is a compact, tunable, high-brightness, ultra-short-pulse, Thomson-scattering X-ray source. Picosecond pulses of hard X-rays (10-200 keV) are created by colliding an ultra-relativistic (20-100 MeV), picosecond-duration electron beam with a high-intensity, sub-picosecond, 800-nm laser pulse. Initial operation of this source has produced 78-keV X-rays with 10(6) photons per pulse using a 57-MeV, 0.3-nC, 50-mum rms width electron beam and a 180-mJ, 15-mum rms width laser pulse. The angular distribution, energy, and energy spectrum of the source are found to agree well with theory and simulations. Source optimization is expected to increase X-ray output to between 10(7) and 10(8) photons per pulse with a peak brightness approaching 10(20) photons/s/0.1% bandwidth/mm(2)/mrad(2).
Název v anglickém jazyce
Short-Pulse, High Brightness X-ray Production with the PLEIADES Thomson Scattering Source
Popis výsledku anglicky
PLEIADES is a compact, tunable, high-brightness, ultra-short-pulse, Thomson-scattering X-ray source. Picosecond pulses of hard X-rays (10-200 keV) are created by colliding an ultra-relativistic (20-100 MeV), picosecond-duration electron beam with a high-intensity, sub-picosecond, 800-nm laser pulse. Initial operation of this source has produced 78-keV X-rays with 10(6) photons per pulse using a 57-MeV, 0.3-nC, 50-mum rms width electron beam and a 180-mJ, 15-mum rms width laser pulse. The angular distribution, energy, and energy spectrum of the source are found to agree well with theory and simulations. Source optimization is expected to increase X-ray output to between 10(7) and 10(8) photons per pulse with a peak brightness approaching 10(20) photons/s/0.1% bandwidth/mm(2)/mrad(2).
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů