Maple Processing of Tosylate-Pullulan-Tailor-Made Biomaterial Thin Films for Drug Delivery Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F05%3A00111891" target="_blank" >RIV/68407700:21460/05:00111891 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Maple Processing of Tosylate-Pullulan-Tailor-Made Biomaterial Thin Films for Drug Delivery Systems
Popis výsledku v původním jazyce
We report the successful deposition of tosylate-pullulan by MAPLE using a KrF* excimer laser. The thin films are composed of starting materials preserving their initial chemical structure. We have demonstrated that MAPLE can provide an improved approachto growing high quality thin films of tosylate-pullulan, including an accurate thickness control highly required in targeted drug delivery. The fluence plays a key role in the optimization of the depositions of this polysaccharide. This new pullulan-tailor-made biomaterial with desirable functional groups are potentially used not only for new drug delivery systems but also as substrates for cell growth, and as agents in immunology testing.
Název v anglickém jazyce
Maple Processing of Tosylate-Pullulan-Tailor-Made Biomaterial Thin Films for Drug Delivery Systems
Popis výsledku anglicky
We report the successful deposition of tosylate-pullulan by MAPLE using a KrF* excimer laser. The thin films are composed of starting materials preserving their initial chemical structure. We have demonstrated that MAPLE can provide an improved approachto growing high quality thin films of tosylate-pullulan, including an accurate thickness control highly required in targeted drug delivery. The fluence plays a key role in the optimization of the depositions of this polysaccharide. This new pullulan-tailor-made biomaterial with desirable functional groups are potentially used not only for new drug delivery systems but also as substrates for cell growth, and as agents in immunology testing.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The 3rd European Medical and Biological Engineering Conference - EMBEC´05
ISBN
—
ISSN
1727-1983
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Společnost biomedicínského inženýrství a lékařské informatiky ČLS JEP
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
20. 11. 2005
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—