Využití ablace pevných terčů k charakterizaci fokusovaného měkkého rentgenového svazku
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F07%3A12144056" target="_blank" >RIV/68407700:21460/07:12144056 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilizing ablation of solids to characterize a focused soft x-ray laser beam
Popis výsledku v původním jazyce
An advanced time integrated method has been developed for soft X-ray pulsed laser beam characterization. A technique based on poly (methyl methacrylate) - PMMA laser induced ablation has been used for beam investigations of soft X-ray laser sources likeFLASH (Free-electron LASer in Hamburg; formerly known as VUV FEL and/or TTF2 FEL) and plasma-based Ne-like Zn laser performed at PALS (Prague Asterix Laser System). For the interaction experiments reported here, the FLASH system provided ultra-short pulses (~10-fs) of 21.7-nm radiation. The PMMA ablation was also induced by plasma-based Ne-like Zn soft X-ray laser pumped by NIR beams at the PALS facility. This quasi-steady-state (QSS) soft X-ray laser provides 100-ps pulses of 21.2-nm radiation, i.e. ata wavelength very close to that of FLASH but with about 5,000 times longer pulses. In both cases, the PMMA samples were irradiated by a single shot with a focused beam under normal incidence conditions.
Název v anglickém jazyce
Utilizing ablation of solids to characterize a focused soft x-ray laser beam
Popis výsledku anglicky
An advanced time integrated method has been developed for soft X-ray pulsed laser beam characterization. A technique based on poly (methyl methacrylate) - PMMA laser induced ablation has been used for beam investigations of soft X-ray laser sources likeFLASH (Free-electron LASer in Hamburg; formerly known as VUV FEL and/or TTF2 FEL) and plasma-based Ne-like Zn laser performed at PALS (Prague Asterix Laser System). For the interaction experiments reported here, the FLASH system provided ultra-short pulses (~10-fs) of 21.7-nm radiation. The PMMA ablation was also induced by plasma-based Ne-like Zn soft X-ray laser pumped by NIR beams at the PALS facility. This quasi-steady-state (QSS) soft X-ray laser provides 100-ps pulses of 21.2-nm radiation, i.e. ata wavelength very close to that of FLASH but with about 5,000 times longer pulses. In both cases, the PMMA samples were irradiated by a single shot with a focused beam under normal incidence conditions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KAN300100702" target="_blank" >KAN300100702: Vytváření a charakterizace nanostruktur rentgenovými lasery</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Adaptive Optics for Laser Systems and Other Applications
ISBN
978-0-8194-6712-6
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
"65860S"-65860S"
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Prague
Datum konání akce
16. 4. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—