Název v původním jazyce
Advanced Monitoring System for Conventional and High-Frequency Ventilation
Popis výsledku v původním jazyce
The article deals with advanced monitoring techniques of artificial lung ventilation and modelling of the respiratory system. For these purposes, the unique system has been created which is able to measure basic ventilatory parameters as other monitoringdevices but it is also capable to measure oesophageal and intraabdominal pressures and to evaluate isolated parameters of the chest wall and lungs. Furthermore, the system is able to model mechanical characteristics of the respiratory system, especiallythe alveolar pressure, in real-time. The most important features of system are patient's safety, user friendly design and possibility of storing the measured data in a database system for next statistical and clinical evaluation. The accuracy has been confirmed by a commercial ventilator Amadeus (Hamilton Medical, Rhäzüns, Switzerland). The system has been tested during animal experiments and during a human clinical trial in a faculty hospital.
Název v anglickém jazyce
Advanced Monitoring System for Conventional and High-Frequency Ventilation
Popis výsledku anglicky
The article deals with advanced monitoring techniques of artificial lung ventilation and modelling of the respiratory system. For these purposes, the unique system has been created which is able to measure basic ventilatory parameters as other monitoringdevices but it is also capable to measure oesophageal and intraabdominal pressures and to evaluate isolated parameters of the chest wall and lungs. Furthermore, the system is able to model mechanical characteristics of the respiratory system, especiallythe alveolar pressure, in real-time. The most important features of system are patient's safety, user friendly design and possibility of storing the measured data in a database system for next statistical and clinical evaluation. The accuracy has been confirmed by a commercial ventilator Amadeus (Hamilton Medical, Rhäzüns, Switzerland). The system has been tested during animal experiments and during a human clinical trial in a faculty hospital.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika
ISSN
0301-5491
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—