Vliv krystalihity na biofyzikální vlastnosti tenkých vrstev hydroxyapatitu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F08%3A12148471" target="_blank" >RIV/68407700:21460/08:12148471 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of crystallinity on bio-physical properties of hydroxapatite films
Popis výsledku v původním jazyce
Crystalline and amorphous hydroxapatite (HA) films were prepared by KrF pulsed laser deposition method. Influence of HA structure on biomedical properties was studied. Crystallinity, morphology, composition, optical transmission and mechanical properties(adhesion) were measured. Biomedical properties were tested using human dermal fibroblast. The specific proteins (vimentin, fibronectin, pankeratin, keratin 14) were visualized. The worst proliferation of fibroblasts was observed on the amophous coating, whereas the adhesion was well comparable with other surfaces. The level of keratinocyte differentiation on the amorphous and crystalline HA coating was the same. Results reached on physical and mechanical properties are discussed in connection with results of in vitro tests.
Název v anglickém jazyce
Influence of crystallinity on bio-physical properties of hydroxapatite films
Popis výsledku anglicky
Crystalline and amorphous hydroxapatite (HA) films were prepared by KrF pulsed laser deposition method. Influence of HA structure on biomedical properties was studied. Crystallinity, morphology, composition, optical transmission and mechanical properties(adhesion) were measured. Biomedical properties were tested using human dermal fibroblast. The specific proteins (vimentin, fibronectin, pankeratin, keratin 14) were visualized. The worst proliferation of fibroblasts was observed on the amophous coating, whereas the adhesion was well comparable with other surfaces. The level of keratinocyte differentiation on the amorphous and crystalline HA coating was the same. Results reached on physical and mechanical properties are discussed in connection with results of in vitro tests.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
4th Kuala Lumpur International Conference on Biomedical Engineering
ISBN
978-3-540-69139-6
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
3
Strana od-do
—
Název nakladatele
Springer
Místo vydání
Heidelberg
Místo konání akce
Kuala Lumpur
Datum konání akce
25. 6. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—