Human Downfall Simulation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F09%3A00185524" target="_blank" >RIV/68407700:21460/09:00185524 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Human Downfall Simulation
Popis výsledku v původním jazyce
Total knee and hip implants are usually designed for the static load of standing man, but the static load is not extreme. The top of research is to search extreme values forces and moments at leg and arm joints. The implants can be then designed for these extreme dynamics loads. Human fall was observed by camera system to record the position data of main points on human body. The 3D coordinates of the end of foot, ankle, knee, hip, pelvis, shoulder and wrist were stored. The simulation program of humanfall was compiled at PC in language C++ using simulation system CDCSIS. The program has an input data - length, mass and inertia moments for each part of human body. The data are transformed according to actual coordinates of points on the body. Then themoving and turning accelerations are calculated and joint forces and moments are determined according to the d'Alembert's principle. At the conclusion the noise is canceled.
Název v anglickém jazyce
Human Downfall Simulation
Popis výsledku anglicky
Total knee and hip implants are usually designed for the static load of standing man, but the static load is not extreme. The top of research is to search extreme values forces and moments at leg and arm joints. The implants can be then designed for these extreme dynamics loads. Human fall was observed by camera system to record the position data of main points on human body. The 3D coordinates of the end of foot, ankle, knee, hip, pelvis, shoulder and wrist were stored. The simulation program of humanfall was compiled at PC in language C++ using simulation system CDCSIS. The program has an input data - length, mass and inertia moments for each part of human body. The data are transformed according to actual coordinates of points on the body. Then themoving and turning accelerations are calculated and joint forces and moments are determined according to the d'Alembert's principle. At the conclusion the noise is canceled.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
RECENT ADVANCES IN MECHATRONICS: 2008-2009
ISBN
978-3-642-05021-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
437-442
Název nakladatele
Springer
Místo vydání
Heidelberg
Místo konání akce
Varšava
Datum konání akce
18. 11. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000277076900074