Mathematical model-based markers of autonomic nervous activity during the Valsalva Maneuver and comparison to heart rate variability
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F11%3A00181705" target="_blank" >RIV/68407700:21460/11:00181705 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mathematical model-based markers of autonomic nervous activity during the Valsalva Maneuver and comparison to heart rate variability
Popis výsledku v původním jazyce
This work exhibits limitations of some time-frequency markers of heart rate variability (SDNN: standard deviation of normal-to-normal intervals, RMSSD: root mean square successive difference of normal-tonormal intervals, LF: power of low frequency components 0.015-0.15 Hz, HF: power of high frequency components 0.15-0.4 Hz) as tool for assessing autonomic nervous activity on the cardiovascular system during the Valsalva Maneuver (VM) and proposes a new approach based on a physiologically based mathematical model. Our mathematical model fits measured heart rate and galvanic skin response during intra-thoracic and intra-abdominal pressure elevation, simulates the baroreflex and estimates parameters that should quantify mean autonomic tone of parasympathetic activity (MATpar), maximal autonomic tone of parasympathetic activity (MATpar, total autonomic tone of sympathetic activity (TATsym) and autonomic tone balance (ATB) on 5 healthy subjects.
Název v anglickém jazyce
Mathematical model-based markers of autonomic nervous activity during the Valsalva Maneuver and comparison to heart rate variability
Popis výsledku anglicky
This work exhibits limitations of some time-frequency markers of heart rate variability (SDNN: standard deviation of normal-to-normal intervals, RMSSD: root mean square successive difference of normal-tonormal intervals, LF: power of low frequency components 0.015-0.15 Hz, HF: power of high frequency components 0.15-0.4 Hz) as tool for assessing autonomic nervous activity on the cardiovascular system during the Valsalva Maneuver (VM) and proposes a new approach based on a physiologically based mathematical model. Our mathematical model fits measured heart rate and galvanic skin response during intra-thoracic and intra-abdominal pressure elevation, simulates the baroreflex and estimates parameters that should quantify mean autonomic tone of parasympathetic activity (MATpar), maximal autonomic tone of parasympathetic activity (MATpar, total autonomic tone of sympathetic activity (TATsym) and autonomic tone balance (ATB) on 5 healthy subjects.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Signal Processing and Control
ISSN
1746-8094
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
251-260
Kód UT WoS článku
000293480100006
EID výsledku v databázi Scopus
—