Design and Control of a Demand Flow System Assuring Spontaneous Breathing of a Patient Connected to an HFO Ventilator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F11%3A00184171" target="_blank" >RIV/68407700:21460/11:00184171 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=5993522" target="_blank" >http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=5993522</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TBME.2011.2165541" target="_blank" >10.1109/TBME.2011.2165541</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design and Control of a Demand Flow System Assuring Spontaneous Breathing of a Patient Connected to an HFO Ventilator
Popis výsledku v původním jazyce
Lung protective ventilation is intended to minimize the risk of ventilator induced lung injury and currently aimed at preservation of spontaneous breathing during mechanical ventilation. High-frequency oscillatory ventilation (HFOV) is a lung protectiveventilation strategy. Commonly used high-frequency oscillatory (HFO) ventilators, SensorMedics 3100, were not designed to tolerate spontaneous breathing. Respiratory efforts in large pediatric and adult patients impose a high workload to the patient andmay cause pressure swings that impede ventilator function. A Demand Flow System (DFS) was designed to facilitate spontaneous breathing during HFOV. Using a linear quadratic Gaussian state feedback controller, the DFS alters the inflow of gas into the ventilator circuit, so that it instantaneously compensates for the changes in mean airway pressure (MAP) in the ventilator circuit caused by spontaneous breathing. The undesired swings in MAP are thus eliminated.
Název v anglickém jazyce
Design and Control of a Demand Flow System Assuring Spontaneous Breathing of a Patient Connected to an HFO Ventilator
Popis výsledku anglicky
Lung protective ventilation is intended to minimize the risk of ventilator induced lung injury and currently aimed at preservation of spontaneous breathing during mechanical ventilation. High-frequency oscillatory ventilation (HFOV) is a lung protectiveventilation strategy. Commonly used high-frequency oscillatory (HFO) ventilators, SensorMedics 3100, were not designed to tolerate spontaneous breathing. Respiratory efforts in large pediatric and adult patients impose a high workload to the patient andmay cause pressure swings that impede ventilator function. A Demand Flow System (DFS) was designed to facilitate spontaneous breathing during HFOV. Using a linear quadratic Gaussian state feedback controller, the DFS alters the inflow of gas into the ventilator circuit, so that it instantaneously compensates for the changes in mean airway pressure (MAP) in the ventilator circuit caused by spontaneous breathing. The undesired swings in MAP are thus eliminated.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD102%2F08%2FH018" target="_blank" >GD102/08/H018: Modelování a simulace polí</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Transactions on Biomedical Engineering
ISSN
0018-9294
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
3225-3233
Kód UT WoS článku
000296019500021
EID výsledku v databázi Scopus
—