Time-domain UV-VIS luminescence spectrometer for characterization of luminescence kinetics of solids excited by nanosecond pulse of soft X-ray source and/or UV laser
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F12%3A00190843" target="_blank" >RIV/68407700:21460/12:00190843 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.fbmi.cvut.cz/fvz/190843" target="_blank" >http://www.fbmi.cvut.cz/fvz/190843</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Time-domain UV-VIS luminescence spectrometer for characterization of luminescence kinetics of solids excited by nanosecond pulse of soft X-ray source and/or UV laser
Popis výsledku v původním jazyce
The table-top, time-domain UV-VIS luminescence spectrometer, featuring extended time and input sensitivity ranges and two excitation sources, is used for the comparative measurements of luminescence spectra and decay kinetics of scintillators. The luminescence of emission centers of a doped scintillator can be induced by conventional N2 laser pulse, while the complete scintillation process can be initiated by a soft X-ray/XUV pulse excitation from the laser-produced plasma in nitrogen gas puff target of4 ns duration. The advantage of the presently developed instrumentation for the measurement of scintillation response under XUV nanosecond pulses of low repetition frequency consists in extreme sensitivity given by very high absorption of ionizing XUV excitation in the sample (100 nm) and photomultiplier-based detection with averaging-feature of fast digital oscilloscope.
Název v anglickém jazyce
Time-domain UV-VIS luminescence spectrometer for characterization of luminescence kinetics of solids excited by nanosecond pulse of soft X-ray source and/or UV laser
Popis výsledku anglicky
The table-top, time-domain UV-VIS luminescence spectrometer, featuring extended time and input sensitivity ranges and two excitation sources, is used for the comparative measurements of luminescence spectra and decay kinetics of scintillators. The luminescence of emission centers of a doped scintillator can be induced by conventional N2 laser pulse, while the complete scintillation process can be initiated by a soft X-ray/XUV pulse excitation from the laser-produced plasma in nitrogen gas puff target of4 ns duration. The advantage of the presently developed instrumentation for the measurement of scintillation response under XUV nanosecond pulses of low repetition frequency consists in extreme sensitivity given by very high absorption of ionizing XUV excitation in the sample (100 nm) and photomultiplier-based detection with averaging-feature of fast digital oscilloscope.
Klasifikace
Druh
G<sub>funk</sub> - Funkční vzorek
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KAN300100702" target="_blank" >KAN300100702: Vytváření a charakterizace nanostruktur rentgenovými lasery</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Interní identifikační kód produktu
XUV/UV/VIS luminiscenční spektro
Číselná identifikace
—
Technické parametry
rozměry: 2000x1000x750mm; hmotnost: 70 kg; napájení: 230V; provozní teplota 18-25 °C; rozsah detekovaných vlnových délek: 200-600nm, časová instrumentální odezva: 4 ns, max. velikost vzorku: 25x25x5mm
Ekonomické parametry
pouze pro nekomerční využití
Kategorie aplik. výsledku dle nákladů
—
IČO vlastníka výsledku
68407700
Název vlastníka
ČVUT FBMI
Stát vlastníka
CZ - Česká republika
Druh možnosti využití
N - Využití výsledku jiným subjektem je možné bez nabytí licence (výsledek není licencován)
Požadavek na licenční poplatek
—
Adresa www stránky s výsledkem
—