Evaluation of Muscular Moment Asymmetry using Bilateral Cyclograms
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F14%3A00222712" target="_blank" >RIV/68407700:21460/14:00222712 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7018291" target="_blank" >http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7018291</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/MECHATRONIKA.2014.7018291" target="_blank" >10.1109/MECHATRONIKA.2014.7018291</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Muscular Moment Asymmetry using Bilateral Cyclograms
Popis výsledku v původním jazyce
Knowledge of bilateral asymmetry of moments of muscle forces is important because a ?weak? muscle that is not fully ready to create the required moment can be identified and restored to provide symmetric gait. However, there is currently no method to determine the symmetry of muscular moments of the left and right sides of body during walking. Recently, new technique based on the geometric properties of symmetric diagrams, also called bilateral cyclograms, was introduced. In order to quantify the symmetry of muscular moments, a bilateral synchronized cyclogram which represents the same gait variables, i.e. moments, and two sides of the body was used. For symmetric gait, cyclogram should lie on a symmetry line passing through the origin inclined at an angle 45?. To study the gait variables, gait measurement was performed using a MoCap system (VICON MX; Oxford Metrics) and four force plates (AMTI, Advanced Mechanical Technology). Calculations of parameters of gait were performed using th
Název v anglickém jazyce
Evaluation of Muscular Moment Asymmetry using Bilateral Cyclograms
Popis výsledku anglicky
Knowledge of bilateral asymmetry of moments of muscle forces is important because a ?weak? muscle that is not fully ready to create the required moment can be identified and restored to provide symmetric gait. However, there is currently no method to determine the symmetry of muscular moments of the left and right sides of body during walking. Recently, new technique based on the geometric properties of symmetric diagrams, also called bilateral cyclograms, was introduced. In order to quantify the symmetry of muscular moments, a bilateral synchronized cyclogram which represents the same gait variables, i.e. moments, and two sides of the body was used. For symmetric gait, cyclogram should lie on a symmetry line passing through the origin inclined at an angle 45?. To study the gait variables, gait measurement was performed using a MoCap system (VICON MX; Oxford Metrics) and four force plates (AMTI, Advanced Mechanical Technology). Calculations of parameters of gait were performed using th
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20102015002" target="_blank" >VG20102015002: Osobní bezpečnostní dohledový systém pro podporu výcviku a zásahu jednotek IZS</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
16th Mechatronika 2014
ISBN
978-80-214-4816-2
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
399-401
Název nakladatele
Brno University of Technology
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
3. 12. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—