Local Skin Exposure of Hands of Workers at Selected Pet Nuclear Medicine Departments in the Czech Republic: Recommended Correction Factors Based on Specific Measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F14%3A00223138" target="_blank" >RIV/68407700:21460/14:00223138 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Local Skin Exposure of Hands of Workers at Selected Pet Nuclear Medicine Departments in the Czech Republic: Recommended Correction Factors Based on Specific Measurements
Popis výsledku v původním jazyce
The paper summarizes the local skin exposure of hands of workers at two PET centres in the Czech Republic. Based on three cycles of measurements using thermoluminescent dosimeters, the maximum local skin exposure of hands of workers engaged in dispensingor administering the 18F-labeled radiopharmaceutical has been determined. In addition, the annual hand exposure has been estimated and the relevant correction factors to be used at these centres have been recommended. As to the persons dispensing radiopharmaceuticals, it was estimated that 50% of them can reach the equivalent dose corresponding to the reference level of 150 mSv/y. In the case of the workers administering radiopharmaceutical, it was estimated that 43 % of cases can reach investigation level
Název v anglickém jazyce
Local Skin Exposure of Hands of Workers at Selected Pet Nuclear Medicine Departments in the Czech Republic: Recommended Correction Factors Based on Specific Measurements
Popis výsledku anglicky
The paper summarizes the local skin exposure of hands of workers at two PET centres in the Czech Republic. Based on three cycles of measurements using thermoluminescent dosimeters, the maximum local skin exposure of hands of workers engaged in dispensingor administering the 18F-labeled radiopharmaceutical has been determined. In addition, the annual hand exposure has been estimated and the relevant correction factors to be used at these centres have been recommended. As to the persons dispensing radiopharmaceuticals, it was estimated that 50% of them can reach the equivalent dose corresponding to the reference level of 150 mSv/y. In the case of the workers administering radiopharmaceutical, it was estimated that 43 % of cases can reach investigation level
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
AQ - Bezpečnost a ochrana zdraví, člověk – stroj
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
5. mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky
ISBN
978-80-87952-07-8
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
3665-3671
Název nakladatele
MAGNANIMITAS
Místo vydání
Hradec Králové
Místo konání akce
Hradec Králové
Datum konání akce
15. 12. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce