Two Cameras Motion Capture System For Bradykinesia Measurement In Parkinson Disease
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F14%3A00226191" target="_blank" >RIV/68407700:21460/14:00226191 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Two Cameras Motion Capture System For Bradykinesia Measurement In Parkinson Disease
Popis výsledku v původním jazyce
Parkinson?s disease (PD) is a chronic neurodegenerative disorder that affects almost 1% of the population in the age group above 60 years. The key symptom in PD is the restriction of mobility. The progress of PD is typically documented using the UnifiedParkinson?s Disease Rating Scale (UPDRS), which includes a finger-tapping test... We created a measurement tool and a methodology for the objective measurement of the finger-tapping test. We built a contactless three-dimensional (3D) capture system usingtwo cameras and light-passive (wireless) reflexive markers. We proposed and implemented an algorithm for extracting, matching, and tracing markers. The system provides the 3D position of spherical or hemispherical markers in real time. Our motion capture system is easy to use, saves space, is transportable, and needs only a personal computer for data processing?the ideal solution for an outpatient clinic.The system?s functionality was verified with the commercial motion capture system O
Název v anglickém jazyce
Two Cameras Motion Capture System For Bradykinesia Measurement In Parkinson Disease
Popis výsledku anglicky
Parkinson?s disease (PD) is a chronic neurodegenerative disorder that affects almost 1% of the population in the age group above 60 years. The key symptom in PD is the restriction of mobility. The progress of PD is typically documented using the UnifiedParkinson?s Disease Rating Scale (UPDRS), which includes a finger-tapping test... We created a measurement tool and a methodology for the objective measurement of the finger-tapping test. We built a contactless three-dimensional (3D) capture system usingtwo cameras and light-passive (wireless) reflexive markers. We proposed and implemented an algorithm for extracting, matching, and tracing markers. The system provides the 3D position of spherical or hemispherical markers in real time. Our motion capture system is easy to use, saves space, is transportable, and needs only a personal computer for data processing?the ideal solution for an outpatient clinic.The system?s functionality was verified with the commercial motion capture system O
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT14181" target="_blank" >NT14181: Analýza bradykineze a poruch řeči u Parkinsonovy nemoci</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník příspěvků MEDSOFT 2014
ISBN
978-80-86742-38-0
ISSN
1803-8115
e-ISSN
—
Počet stran výsledku
10
Strana od-do
211-220
Název nakladatele
Creative Connections
Místo vydání
Praha
Místo konání akce
Roztoky u Prahy
Datum konání akce
25. 3. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—