Intraocular Pressure in Ophthalmological Practice

Identifikátory výsledku

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Intraocular Pressure in Ophthalmological Practice

  • Popis výsledku v původním jazyce

    Objective: To determine whether we are able to obtain the same values of intraocular pressure using three different non-contact devices. Patients and methods of examination: The study included 100 eyes of 50 people, of whom 25 were women (25-82 years) and 25 men (21-81 years). The first group included 12 glaucoma patients (6 on prostaglandins) and 13 healthy individuals. The second group included 8 glaucoma patients (3 on prostaglandins) and 17 healthy subjects. Intraocular pressure (IOP) was measured by three devices: non-contact Tonometer TX-F, non-contact Tonometer TX-20P (Canon) incorporating optical pachymeter, and Ocular Response Analyser II (Reichert). To eliminate the role of corneal thickness on IOP, the Tomey Handy Pachymeter SP100 was used with the noncontact Tonometer TX-F. The time difference between individual measurements was 15-30 minutes. Results: CCT US (central corneal thickness measured by ultrasound) values were statistically significantly higher than CCT OB (centr

  • Název v anglickém jazyce

    Intraocular Pressure in Ophthalmological Practice

  • Popis výsledku anglicky

    Objective: To determine whether we are able to obtain the same values of intraocular pressure using three different non-contact devices. Patients and methods of examination: The study included 100 eyes of 50 people, of whom 25 were women (25-82 years) and 25 men (21-81 years). The first group included 12 glaucoma patients (6 on prostaglandins) and 13 healthy individuals. The second group included 8 glaucoma patients (3 on prostaglandins) and 17 healthy subjects. Intraocular pressure (IOP) was measured by three devices: non-contact Tonometer TX-F, non-contact Tonometer TX-20P (Canon) incorporating optical pachymeter, and Ocular Response Analyser II (Reichert). To eliminate the role of corneal thickness on IOP, the Tomey Handy Pachymeter SP100 was used with the noncontact Tonometer TX-F. The time difference between individual measurements was 15-30 minutes. Results: CCT US (central corneal thickness measured by ultrasound) values were statistically significantly higher than CCT OB (centr

Klasifikace

  • Druh

    Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)

  • CEP obor

    FF - ORL, oftalmologie, stomatologie

  • OECD FORD obor

Návaznosti výsledku

Ostatní

  • Rok uplatnění

    2015

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Sylwan

  • ISSN

    0039-7660

  • e-ISSN

  • Svazek periodika

    159

  • Číslo periodika v rámci svazku

    6

  • Stát vydavatele periodika

    PL - Polská republika

  • Počet stran výsledku

    16

  • Strana od-do

    243-258

  • Kód UT WoS článku

  • EID výsledku v databázi Scopus